To verify the host side, For internal use only – Sun Microsystems StorEdge 6900 Series User Manual

Page 53

Advertising
background image

Chapter 3

Troubleshooting the Fibre Channel Links

37

For Internal Use Only

To Verify the Host Side

An error in the A3/B3 FC link results in a device being listed as in an “unusable”
state in

cfgadm

, but no HBAs are listed as in the “unconnected” state in

luxadm

output. The multipathing software will note an “offline” path.

CODE EXAMPLE 3-5

Devices in the “connected” state

# cfgadm -al

Ap_Id

Type

Receptacle

Occupant

Condition

c0

scsi-bus

connected

configured

unknown

c0::dsk/c0t0d0

disk

connected

configured

unknown

c0::dsk/c0t1d0

disk

connected

configured

unknown

c1

scsi-bus

connected

configured

unknown

c1::dsk/c1t6d0

CD-ROM

connected

configured

unknown

c2

fc-fabric

connected

configured

unknown

c2::210100e08b23fa25

unknown

connected

unconfigured unknown

c2::2b000060220041f4

disk

connected

configured

unknown

c3

fc-fabric

connected

configured

unknown

c3::2b000060220041f9

disk

connected

configured

unusable

c3::210100e08b230926

unknown

connected

unconfigured unknown

c4

fc-private

connected

unconfigured unknown

c5

fc

connected

unconfigured unknown

# luxadm -e port

Found path to 2 HBA ports

/devices/pci@6,4000/SUNW,qlc@2/fp@0,0:devctl

CONNECTED

/devices/pci@6,4000/SUNW,qlc@3/fp@0,0:devctl

CONNECTED

# luxadm display

/dev/rdsk/c6t29000060220041F96257354230303052d0s2

DEVICE PROPERTIES for disk: /dev/rdsk/

c6t29000060220041F96257354230303052d0s2

<snip>

/devices/scsi_vhci/ssd@g29000060220041f96257354230303052:c,raw

Controller /devices/pci@6,4000/SUNW,qlc@3/fp@0,0

Device Address 2b000060220041f9,0

Class primary

State OFFLINE

Controller /devices/pci@6,4000/SUNW,qlc@2/fp@0,0

Device Address 2b000060220041f4,0

Class primary

State ONLINE

Advertising