CODE EXAMPLE 7-1

Fibre Channel Link Error Status Example

Note –

v1

represents the first virtualization engine pair

Note –

The

SLIC

daemon must be running for the

/opt/svengine/sduc/svstat -d v1

command to work.

# /opt/svengine/sduc/svstat -d v1

I00001 Host Side FC Vital Statistics:

Link Failure Count 0

Loss of Sync Count 0

Loss of Signal Count 0

Protocol Error Count 0

Invalid Word Count 8

Invalid CRC Count 0

I00001 Device Side FC Vital Statistics:

Link Failure Count 0

Loss of Sync Count 0

Loss of Signal Count 0

Protocol Error Count 0

Invalid Word Count 139

Invalid CRC Count 0

I00002 Host Side FC Vital Statistics:

Link Failure Count 0

Loss of Sync Count 0

Loss of Signal Count 0

Protocol Error Count 0

Invalid Word Count 11

Invalid CRC Count 0

I00002 Device Side FC Vital Statistics:

Link Failure Count 0

Loss of Sync Count 0

Loss of Signal Count 0

Protocol Error Count 0

Invalid Word Count 135

Invalid CRC Count 0

diag.xxxxx.xxx.com: root#