Sun Microsystems StorEdge 6900 Series User Manual

Page 80

Advertising
background image

64

Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002

TABLE 6-1

lists the switch events.

TABLE 6-1

Storage Automated Diagnostic Environment Event Grid for Switches

Cat

Component

EventType

Sev

Action

Description

Information/Action

switch

port statistics

Log

Yellow

Y

[ Info/Action ]

Change in port
statistics on switch

diag156-sw1b

(

ip=192.168.0.31

)

Information: The
switch has reported
a change in an error
counter. This could
indicate a failing
component in the
link.

Action:
Check the Topology
GUI for any link
errors.
Run linktest on the
link to isolate the
failing FRU. Quiesce
I/O on the link
before running
linktest.

switch

chassis.fan

Alarm

Yellow

chassis.fan.1 status
changed from OK

switch

chassis.power

Alarm

Yellow

[ Info ]
chassis.power.1 status
changed from OK

This event monitors
changes in the
status of the chassis’
power supply, as
reported by SANbox
chassis_status.

switch

chassis.temp

Alarm

Yellow

[ Info ] chassis.temp.1
status changed from
OK

This event monitors
changes in the
status of the chassis’
temperature supply,
as reported by
SANbox
chassis_status.

switch

chassis.zone

Alarm

Yellow

[ Info ] Switch sw1a
was rezoned: [ new
zones ...]

This event reports
changes in the
zoning of a switch.

Advertising
This manual is related to the following products: