Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002

t3

ib

Comm_Lost

Down

Y

[ Info/Action ] Lost

communication
(InBandwith

diag213

(ip=xxx.20.67.21

3)

( last reboot was

2001-09-27 15:22:00)

Information: InBand.
This event is
established using

luxadm

. This

monitoring may not
be activated for a
particular Sun
StorEdge T3+ array.

Recommended action:
1. Verify

luxadm

via

command line
(luxadm probe,
luxadm display)

2. Verify cables,

GBICs and
connections along
data path.

3. Check the Storage

Automated
Diagnostic
Environment SAN
Topology GUI to
identify the failing
segment of the
data path.

4. Verify the correct

FC switch
configuration, if
applicable.

t3

oob

Comm_Lost

Down

Y

[ Info/Action ] Lost

communication
(OutOfBand with

diag213

(

ip

=xxx

.20.67.212

)

Probable Cause: This
problem can also be
caused by a very slow
network, or because
the Ethernet
connection to this Sun
StorEdge T3+ array
was lost.

Information:

OutOfBand. This
means that the Sun
StorEdge T3+ array
failed to answer to a
ping or failed to
return its tokens.

Recommended action:
1. Check Ethernet

connectivity to the
affected Sun
StorEdge T3+
array.

2. Verify the Sun

StorEdge T3+ array
is booted correctly.

3. Verify the correct

TCP/IP settings on
the Sun StorEdge
T3+ array .

4. Increase the http

and/or ping
timeout in

Utilities--

>System--

>System--

>Timeouts

. The

current default
timeouts are 10
seconds for ping
and 60 seconds for
http (tokens).

Category

Component

EventType

Sev

Action

Description

Information

Advertising