Telnet to affected sun storedge t3+ array, Verify tje loopcard state with fru stat, Re-enable the disk if possible – Sun Microsystems StorEdge 6900 Series User Manual

Page 126: Replace the disk, if necessary

Advertising
background image

110

Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002

The following table lists all of the events for the Sun StorEdge T3+ array.

Category

Component

EventType

Sev

Action

Description

Information

t3

power.temp

Alarm+

The state of
power.u1pcu1.PowTe
mp on diag213
(ip=xxx.20.67.213) is
Normal

t3

disk.port

Alarm-

Red

Y

[ Info/Action ] The
state of

disk.u1d1.

Port1State

on Sun

StorEdge T3+ array
t300 changed from OK
to failed.

Information: The Sun
StorEdge T3+ array
has reported that one
port of a dual-ported
disk has failed.

Recommended action:
1. Telnet to affected

Sun StorEdge T3+
array

2. Verify disk state in

fru stat, fru list,
and vol stat.’

t3

interface.
loopcard.cab
le

Alarm-

Red

Y

[ Info/Action ] The

state of
loopcable.u1l1.CableSt
ate changed from OK
to failed.

Drive Status
Messages:
Value Description
0 Drive mounted
2 Drive present
3 Drive is spun up
4 Drive is disable
5 Drive has been
replaced
7 Invalid system area
on drive
9 Drive not present
D Drive disabled;
drive is being
reconstructed
S Drive substituted

Information: The Sun
StorEdge T3+ array
has reported that a
loopcard is in a failed
state.

Recommended action:
1. Telnet to affected

Sun StorEdge T3+
array.

2. Verify tje loopcard

state with fru stat.

3. Verify the

matching firmware
with the other
loopcard.

4. Re-enable the

loopcard if
possible (

enable

u (encid)|[1|2]

). Replace loopcard
if necessary.

5. Re-enable the disk

if possible

6. Replace the disk, if

necessary.

Advertising
This manual is related to the following products: