For internal use only – Sun Microsystems StorEdge 6900 Series User Manual

Page 23

Advertising
background image

Chapter 2

General Troubleshooting Procedures

7

For Internal Use Only

Multipathing Options in the Sun
StorEdge 6900 Series

Using the virtualization engines presents several challenges in how multipathing is
handled in the Sun StorEdge 6900 series.

Unlike Sun StorEdge T3+ array and Sun StorEdge network FC switch-8 and switch-
16 switch installations, which present primary and secondary pathing options, the
virtualization engines present only primary pathing options to the data host. The
virtualization engines handle all failover and failback operations and mask those
operations from the multipathing software on the data host.

The following example illustrates a Sun StorEdge Traffic Manager problem on a Sun
StorEdge 6900 series system.

# luxadm display

/dev/rdsk/c6t29000060220041F96257354230303052d0s2

DEVICE PROPERTIES for disk: /dev/rdsk/

c6t29000060220041F96257354230303052d0s2

Status(Port A): O.K.

Status(Port B): O.K.

Vendor: SUN

Product ID: SESS01

WWN(Node): 2a000060220041f4

WWN(Port A): 2b000060220041f4

WWN(Port B): 2b000060220041f9

Revision: 080C

Serial Num: Unsupported

Unformatted capacity: 102400.000 MBytes

Write Cache: Enabled

Read Cache: Enabled

Minimum prefetch: 0x0

Maximum prefetch: 0x0

Device Type: Disk device

Path(s):

/dev/rdsk/c6t29000060220041F96257354230303052d0s2

/devices/scsi_vhci/ssd@g29000060220041f96257354230303052:c,raw

Controller /devices/pci@6,4000/SUNW,qlc@2/fp@0,0

Device Address 2b000060220041f4,0

Class primary

State ONLINE

Controller /devices/pci@6,4000/SUNW,qlc@3/fp@0,0

Device Address 2b000060220041f9,0

Class primary

State ONLINE