To suspend the i/o, To return the path to production, Type cfgadm -c configure device – Sun Microsystems StorEdge 6900 Series User Manual

Page 26: Verify that i/o has resumed on all paths

Advertising
background image

10

Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002

▼

To Suspend the I/O

Use one of the following methods to suspend the I/O while the failover occurs:

1. Stop all customer applications that are accessing the Sun StorEdge T3+ array.

2. Manually pull the link from the Sun StorEdge T3+ array to the switch and wait

for a Sun StorEdge T3+ array LUN failover.

■

After the failover occurs, replace the cable and proceed with testing and FRU
isolation.

■

After testing and any FRU replacement is finished, return the Controller state
back to the default by using virtualization engine failback. Refer to
“Virtualization Engine Failback” on page 81.

Note –

To confirm that a failover is occurring, open a telnet session to the Sun

StorEdge T3+ array and check the output of

port listmap

.

Another, but slower, method is to run the

runsecfg

script and verify the

virtualization engine maps by polling them against a live system.

Caution –

During the failover, SCSI errors will occur on the data host and a brief

suspension of I/O will occur.

▼

To Return the Path to Production

1. Type

cfgadm -c configure

device.

2. Verify that I/O has resumed on all paths.

# cfgadm -c configure c2::2b000060220041f4

Advertising