To suspend the i/o, To return the path to production, Type cfgadm -c configure device – Sun Microsystems StorEdge 6900 Series User Manual

Page 26: Verify that i/o has resumed on all paths

Advertising
background image

10

Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002

To Suspend the I/O

Use one of the following methods to suspend the I/O while the failover occurs:

1. Stop all customer applications that are accessing the Sun StorEdge T3+ array.

2. Manually pull the link from the Sun StorEdge T3+ array to the switch and wait

for a Sun StorEdge T3+ array LUN failover.

After the failover occurs, replace the cable and proceed with testing and FRU
isolation.

After testing and any FRU replacement is finished, return the Controller state
back to the default by using virtualization engine failback. Refer to
“Virtualization Engine Failback” on page 81.

Note –

To confirm that a failover is occurring, open a telnet session to the Sun

StorEdge T3+ array and check the output of

port listmap

.

Another, but slower, method is to run the

runsecfg

script and verify the

virtualization engine maps by polling them against a live system.

Caution –

During the failover, SCSI errors will occur on the data host and a brief

suspension of I/O will occur.

To Return the Path to Production

1. Type

cfgadm -c configure

device.

2. Verify that I/O has resumed on all paths.

# cfgadm -c configure c2::2b000060220041f4

Advertising
This manual is related to the following products: