To verify the a2/b2 fc link, Fru tests available for a2/b2 fc link segment, To isolate the a2/b2 fc link – Sun Microsystems StorEdge 6900 Series User Manual

Page 49: For internal use only

Advertising
background image

Chapter 3

Troubleshooting the Fibre Channel Links

33

For Internal Use Only

Note –

You can find procedures for restoring virtualization engine settings in the

Sun StorEdge 3900 and 6900 Series Reference Manual.

▼

To Verify the A2/B2 FC Link

You can check the A2/B2 FC link using the Storage Automated Diagnostic
Environment, Diagnose—Test from Topology functionality. The Storage Automated
Diagnostic Environment’s implementation of diagnostic tests verifies the operation
of user-selected components. Using the Topology view, you can select specific tests,
subtests, and test options.

Refer to Chapter 5 of the Storage Automated Diagnostic Environment User’s Guide for
more information.

FRU Tests Available for A2/B2 FC Link Segment

■

The

linktest

is not available.

■

The switch and/or GBIC—

switchtest

test:

■

Can be used only in conjunction with the loopback connector.

■

Cannot be cabled to the virtualization engine while

switchtest

runs.

■

No virtualization engine tests are available at this time.

▼

To Isolate the A2/B2 FC Link

1. Quiesce the I/O on the A2/B2 FC link path.

2. Break the connection by uncabling the link.

3. Insert the loopback connector into the switch port.

4. Run

switchtest

:

a. If the test fails, replace the GBIC and rerun

switchtest

.

b. If the test fails again, replace the switch.