To check fibre channel link error status manually – Sun Microsystems StorEdge 6900 Series User Manual

Page 92

Advertising
background image

76

Sun StorEdge 3900 and 6900 Series Troubleshooting Guide — March 2002

To Check Fibre Channel Link Error Status
Manually

The Storage Automated Diagnostic Environment, which runs on the Storage Service
Processor, monitors the Fibre Channel link status of the virtualization engine. The
virtualization engine must be power-cycled to reset the counters. Therefore, you
should manually check the accumulation of errors between a fixed period of time. To
check the status manually, follow these steps:

1. Use the

svstat

command to take a reading, as shown in

CODE EXAMPLE 7-1

.

A Status report for the host-side and device-side ports is displayed.

2. Within the next few minutes, take another reading.

The number of new errors that occurred within that time frame represents the
number of link errors.

Note –

If the

t3ofdg

(1M) is running while you perform these steps, the following

error message is displayed:

Daemon error: check the SLIC router.