When the projection lamp of the projector reaches its end

of life, the Lamp replacement icon appears on the screen

and LAMP REPLACE indicator lights yellow. Replace the

lamp with a new one promptly. The timing when the LAMP

REPLACE indicator should light is depending on the lamp

mode.

For continued safety, replace with a lamp of the

same type. Do not drop a lamp or touch a glass

bulb! The glass can shatter and may cause injury.

Allow a projector to cool for at least 45 minutes

before you open the Lamp Cover. The inside of

the projector can become very hot.

CAUTION

Lamp Replacement

CAUTION

Maintenance and Cleaning

Follow these steps to replace the lamp.

Turn off the projector and unplug the AC power cord.

Let the projector cool for at least 45 minutes.

Loosen the three (3) screws that secure the lamp. Lift

the lamp out of the projector by using the handle.

1

3

Replace the lamp with a new one and secure the three

(3) screws. Make sure that the lamp is set properly.

Close the lamp cover and secure the screw.

4

Loosen the screw and open the lamp cover.

2

Connect the AC power cord to the projector and turn

on the projector.

6

Reset the lamp counter .

See “Resetting the Lamp Counter” on the next page.

5

Lamp Cover

Screw

ORDER REPLACEMENT LAMP

Replacement lamp can be ordered through your dealer. When ordering a projection lamp, give the following

information to the dealer.

Model No . of your projector

: PLC-WL2503

Replacement Lamp Type No .

: POA-LMP141

(Service Parts No. 610 349 0847)

Top Panel

When replacing the lamp because it has stopped illuminating, there is a possibility that the lamp may be

broken. If replacing the lamp of a projector which has been installed on the ceiling, you should always

assume that the lamp is broken, and you should stand to the side of the lamp cover, not underneath it.

Remove the lamp cover gently. Small pieces of glass may fall out when the lamp cover is opened. If pieces

of glass get into your eyes or mouth, seek medical advice immediately.

CAUTION

Screws

Lamp

Handle

Lamp replacement icon

WARNING:

TURN OFF THE UV LAMP BEFORE

OPENING THE LAMP COVER

Note:

The Lamp replacement icon (Fig.1) will not appear

when the Display function is set to

Off (p.46), during

Freeze(p.25), or No show (p.26).

This indicator turns yellow

when the projection lamp

reaches the end of its life.

Advertising