Figure 14.2 asynchronous cycle - using nads, Datasheet – SMSC LAN91C111 User Manual

Page 111

Advertising
background image

10/100 Non-PCI Ethernet Single Chip MAC + PHY

Datasheet

SMSC LAN91C111 REV C

111

Revision 1.91 (08-18-08)

DATASHEET

Figure 14.2 Asynchronous Cycle - Using nADS

PARAMETER

MIN

TYP

MAX

UNITS

t1

A1-A15, AEN, nBE[3:0] Valid to nRD, nWR Active

2

ns

t3

nRD Low to Valid Data

15

ns

t4

nRD High to Data Invalid

2

15

ns

t5

Data Setup to nWR Inactive

10

ns

t5A

Data Hold After nWR Inactive

5

ns

t6

nRD Strobe Width

15

ns

t8

A1-A15, AEN, nBE[3:0] Setup to nADS Rising

8

ns

t9

A1-A15, AEN, nBE[3:0] Hold after nADS Rising

5

ns

t5A

t6

t5

t1

t4

t3

t8

t9

valid

valid

valid

0ns

50ns

100ns

150ns

200ns

250

Addr,AEN,nBE[1:0]

nADS

Read Data

nRD,nWR

Write Data

Asynchronous Cycle -- Using nADS