SMSC LAN91C111 REV C

DATASHEET

REM_FLT- Remote Fault Detect

‘1’ indicates a Remote Fault. Latches the ‘1’ condition and is cleared by reading this register or
resetting the PHY.

CAP_ANEG - AutoNegotiation Capable

Indicates the ability (‘1’) to perform ANEG or not (‘0’).

LINK - Link Status

A ‘1’ indicates a valid Link and a ‘0’ and invalid Link. The ‘0’ condition is latched until this register is
read.

JAB - Jabber Detect

Jabber condition detected when ‘1’ for 10Mbps. ‘1’ latched until this register is read or the PHY is reset.
Always ‘0’ for 100Mbps

EXREG - Extended Capability register

‘1’ Indicates extended registers are implemented

9.3

Register 2&3. PHY Identifier Register

These two registers (offsets 2 and 3) provide a 32-bit value unique to the PHY.

9.4

Register 4. Auto-Negotiation Advertisement Register

This register control the values transmitted by the PHY to the remote partner when advertising its
abilities

REG

BITS

NAME

DEFAULT VALUE

R/W

SOFT RESET

2

15-0

Company ID

0000000000010110

R

Retains Original Value

3

15-10

Company ID

111110

R

Retains Original Value

3

9-4

Manufacturer's ID

000100

R

Retains Original Value

3

3-0

Manufacturer's Revision #

- - - -

R

Retains Original Value

NP

ACK

RF

Reserved

Reserved

Reserved

T4

TX_FDX

RW

R

RW

RW

RW

RW

RW

RW

0

0

0

0

0

0

0

1

TX_HDX

10_FDX

10_HDX

Reserved

Reserved

Reserved

Reserved

CSMA

RW

RW

RW

RW

RW

RW

RW

RW

1

1

1

0

0

0

0

1