19 bank 2 - pointer register, Bank 2 - pointer register, Datasheet – SMSC LAN91C111 User Manual

Page 61

Advertising
background image

10/100 Non-PCI Ethernet Single Chip MAC + PHY

Datasheet

SMSC LAN91C111 REV C

61

Revision 1.91 (08-18-08)

DATASHEET

TEMPTY - No transmit packets in completion queue. For polling purposes, uses the TX_INT bit in the
Interrupt Status Register.

TX FIFO PACKET NUMBER - Packet number presently at the output of the TX FIFO. Only valid if
TEMPTY is clear. The packet is removed when a TX INT acknowledge is issued.

Note: For software compatibility with future versions, the value read from each FIFO register is

intended to be written into the PNR as is, without masking higher bits (provided TEMPTY and
REMPTY = 0 respectively).

8.19

Bank 2 - Pointer Register

POINTER REGISTER - The value of this register determines the address to be accessed within the
transmit or receive areas. It will auto-increment on accesses to the data register when AUTO INCR.
is set. The increment is by one for every byte access, by two for every word access, and by four for
every double word access. When RCV is set the address refers to the receive area and uses the
output of RX FIFO as the packet number, when RCV is clear the address refers to the transmit area
and uses the packet number at the Packet Number Register.

READ - Determines the type of access to follow. If the READ bit is high the operation intended is a
read. If the READ bit is low the operation is a write. Loading a new pointer value, with the READ bit
high, generates a pre-fetch into the Data Register for read purposes.

Readback of the pointer will indicate the value of the address last accessed by the CPU (rather than
the last pre-fetched). This allows any interrupt routine that uses the pointer, to save it and restore it
without affecting the process being interrupted. The Pointer Register should not be loaded until the
Data Register FIFO is empty. The NOT EMPTY bit of this register can be read to determine if the
FIFO is empty. On reads, if ARDY is not connected to the host, the Data Register should not be read
before 370ns after the pointer was loaded to allow the Data Register FIFO to fill.

If the pointer is loaded using 8 bit writes, the low byte should be loaded first and the high byte last.

Reserved - Must be 0

NOT EMPTY - When set indicates that the Write Data FIFO is not empty yet. The CPU can verify that
the FIFO is empty before loading a new pointer value. This is a read only bit.

Note: If AUTO INCR. is not set, the pointer must be loaded with a dword aligned value.

OFFSET

NAME

TYPE

SYMBOL

6

POINTER REGISTER

READ/WRITE

NOT EMPTY IS

A READ ONLY

BIT

PTR

HIGH

BYTE

RCV

AUTO
INCR.

READ

Reserved

NOT

EMPTY

POINTER HIGH

0

0

0

0

0

0

0

0

LOW

BYTE

POINTER LOW

0

0

0

0

0

0

0

0