Series 24-HP Instruction Manual

Chapter 3 Operation

IM-24-HP

3-5

Example for Setting an Output

The following shows how to set Output 1 to measure mass flow with 4 mA = 0 lb/hr and 20 mA = 100 lb/hr with
a time constant of 5 seconds. (All outputs are disabled while using the Setup Menus.)

First, set the desired units of measurement:

1. Use ÕÖ keys to move to the Units Menu (see page 3-9).
2. Press Ø key until Mass Flow Unit appears. Press

ENTER

.

3. Press Ø key until lb appears in the numerator. Press Ö key to move the underline cursor to the

denominator. Press the Ø key until hr appears in the denominator. Press

ENTER

to select.

4. Press × key until Units Menu appears.

Second, set the analog output:

1. Use ÕÖ keys to move to the Output Menu.
2. Press the Ø key until 4-20 mA Output 1 appears.
3. Press Ö key to access Measure selections. Press

ENTER

and press the Ø key to select Mass. Press

ENTER

.

4. Press Ö key to set the 4 mA point in the units you have selected for mass of lb/hr. Press

ENTER

and

use ЧШХЦ keys to set 0 or 0.0. Press

ENTER

.

5. Press Ö key to set the 20 mA point. Press

ENTER

and use ЧШХЦ keys to set 100 or 100.0. Press

ENTER

.

6. Press Ö key to select the Time Constant. Press

ENTER

and use ЧШХЦ keys to select 5. Press

ENTER

.

7. Press the

EXIT

key and answer

YES

to permanently save your changes.