Series 24-HP Instruction Manual

Chapter 3 Operation

IM-24-HP

3-11

Fluid Menu

Password

ENTER

Use
keys to access menus

Fluid

Menu

Flowing Fluid

Liquids >

Goyal-Dorais >

API 2540 >

Nat Gas AGA8 >

Real Gas >

Other Gas >

ENTER

Run Mode

< Liquid

Water

Ammonia

Chlorine

< Mole Weight >

xxxx

STD Press (PSIA)

xxxx

NORM Temp (C)

xxxx

NORM Press

(

KPA

)

xxxx

< CRIT PRESS >

xxxx

< CRIT TEMP >

xxxx

< CRIT Z >

xxxx

< AL >

xxxx

< BL
xxxx

< Density

@

60F >

xxxx

< K0 >

xxxx

< K1 >

xxxx

< AL >

xxxx

< BL

xxxx

< Gas

Steam T

&

P Comp

Steam T Comp

Air

Argon

Ammonia

CO

CO2

Helium

Hydrogen

Methane
Nitrogen

Oxygen

< Rel. Density >

xxxx

< MoleFract N2 >

xxxx

<MoleFract CO2>

xxxx

<RefTemp(F)>

xxxx

< Ref Press(PSIA)

xxxx

< Spec Gravity >

xxxx

< Compress (Z) >

xxxx

< Viscosity

xxxx

STD Temp (F)

xxxx

Steam T Comp

is for VT models

Use the Fluid Menu to configure the flow meter for use with common gases, liquids and steam. Your
flow meter is pre-programmed at the factory for your application’s process fluid.

Reference Richard W. Miller, Flow Measurement Engineering Handbook (Second Edition,
1989),
page 2-67 for definition and use of the Goyal-Doraiswamy equation and page 2-68 for the
definition and use of the API 2540 equation. Also, see Appendix C for Fluid Calculation
equations.

The units of measurement used in the Fluid Menu are preset and are as follows:
Mole Weight = lb

m

/(lb

m

·mol), CRIT PRESS = psia, CRIT TEMP = °R, Density = Kg/m

3

and

Viscosity = cP (centipoise).

Advertising