Appendix A Specifications

IM-24-HP

A-5

Pocess Fluid and

Process Fluid:

Ambient Temperature

Standard temperature sensor: –40° F to 500° F (–40° C to 260° C).

High temperature sensor: to 750° F ( to 400° C).


Ambient:

Operating: –5° F to 140° F (–20° C to 60° C).

Storage: –40° F to 150° F (–40° C to 65° C).

0-98% relative humidity, non-condensing conditions.


Output Signals

(1)

Analog: Volumetric Meter: field rangeable linear 4-20 mA output
signal (1000 Ohms maximum loop resistance) selected by user for
mass flow rate or volumetric flow rate.

Communications: HART, MODBUS, RS485

Multiparameter Meter: up to three field rangeable linear 4-20 mA
output signals (1000 Ohms maximum loop resistance) selected
from the five parameters–mass flow rate, volumetric flow rate, tem-
perature, pressure and density.


Pulse:Pulse output for totalization is a 50-millisecond duration pulse
operating a solid-state relay capable of switching 40 VDC, 40 mA max-
imum.

Note: (1) All outputs are optically isolated and require external power
for operation.


Alarms

Up to three programmable solid-state relays for high, low or window
alarms capable of switching 40 VDC, 40 mA maximum.


Totalizer

Based on user-determined flow units, six significant figures in scien-
tific notation. Total stored in non-volatile memory.

Wetted Materials

Series 240 In-Line Flow Meter:

316L stainless steel standard.

C276 hastelloy or A105 carbon steel optional.

Series 241 Insertion Flow Meter:

316L stainless steel standard.

Teflon

®

packing gland below 500° F (260° C).

Graphite packing gland above 500° F (260° C).


Enclosure

NEMA 4X cast enclosure.


Electrical Ports

Two 3/4-inch female NPT ports.

Mounting Connections

Series 240: Wafer, 150, 300, 600 lb ANSI flange, PN16, PN40,
PN64 flange.

Series 241 Permanent installation: 2-inch MNPT; 150, 300, 600 lb
ANSI flange, PN16, PN40, PN64 flange with compression fitting
probe seal.

Series 241 Hot Tap

(1)

Installation: 2-inch MNPT; 150, 300, 600 lb

ANSI flange, PN16, PN40, PN64 flange and optional retractor with
packing gland probe seal.

Note: (1) Removable under line pressure.


Mounting Position

Series 240 In-Line Flow Meter: No effect.

Series 241 Insertion Flow Meter: Meter must be perpendicular with-
in ± 5° of the pipe centerline.


Certifications Construction

Inspection ( ANSI/ASME B31.3).

Materials (NACE MR-01-75[90]).

CE and FM approved.

CSA, CENELEC approval pending.


FM

approvals:

Class I, Division 1, Groups B, C, & D, T6 at Tamb = 60°C

Class II/III, Division 1, Groups E, F, & G

IP66, NEMA 4X