Lennox Hearth ADAGIO-MP User Manual

Page 14

Advertising
background image

14

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

G. Continue installation of horizontal/inclined

sections - Continue with the installation of the

straight vent sections in horizontal/inclined run

as described in

Step C. Install support straps

every 5' (1.52 m) along horizontal/inclined vent

runs using conventional plumber’s tape.

It is

very important that the horizontal/inclined

run be maintained in a straight (no dips) and

recommended to be in a slightly elevated

plane, in a direction away from the fireplace

of 1/4" rise per foot (20 mm per meter) which

is ideal, though rise per foot run ratios that are

smaller are acceptable all the way down to at or

near level. Use a carpenter’s level to measure

from a constant surface and adjust the support

straps as necessary.

First Vent

Component
Align the dimple (four places)

with the opening of the locking

incline channel on appliance

collar. Twist vent component

clockwise to engage and seal.

Locking

Incline Channel

Dimple

Appliance collar

Vent / Appliance Collar

Connection

Align the dimple (four places) of the

upper vent section with the opening of

the locking incline channel on the

lower vent section. Twist vent

component clockwise to engage and

seal until arrow and dimple align.

Locking

Incline Channel

Dimple

Arrow

Connected

Vent Sections

Vent / Vent Section

Connection

Arrow

Arrow

To attach a vent component to the appliance

collar, align the dimpled end over the collar,

adjusting the radial alignment until the four

locking dimples are aligned with the inlet of

the four inclined channels on the collar (refer

to Figure 15).

Push the vent component against the collar

until it fully engages, then twist the component

clockwise, running the dimples down and along

the incline channels until they seat at the end

of the channels.

The unitized design of the

Secure Vent com-

ponents will engage and seal both the inner

and outer pipe without the need for sealant or

screws. If desired a #6 x 1/2" screw may be

used at the joint, but it is not required as the

pipe will securely lock when twisted.

Figure 15

Figure 17

Figure 16

C. Attach vent components to each other

- Other vent sections may be added to the

previously installed section in accordance with

the requirements of the vertical vent figures

and tables. To add another vent component

to a length of vent run, align the dimpled end

over the inclined channel end of the previously

installed section, adjusting the radial alignment

until the four locking dimples are aligned with

the inlets of the four incline channels of the

previous section.

Push the vent component against the previous

section until it fully engages, then twist the

component clockwise running the dimples down

and along the incline channels until they seat at

the end of the channels. This seating position

is indicated by the alignment of the arrow and

dimple as shown in Figure 16.

D. Install firestop/spacer at ceiling - When

using Secure Vent, use SV4.5VF firestop/spacer

at ceiling joists; when using Secure Flex, use

SF4.5VF firestop/spacer. If there is living space

above the ceiling level, the firestop/spacer

must be installed on the bottom side of the

ceiling. If attic space is above the ceiling, the

firestop/spacer must be installed on the top

side of the joist.

Route the vent sections through the framed

opening and secure the firestop/spacer with

8d nails or other appropriate fasteners at each

corner. Remember to maintain 1" (25 mm)

clearance to combustibles, framing members,

and attic or ceiling insulation when running

vertical chimney sections. Attic insulation

shield may be used to obtain the required

clearances indicated here (order H907,

SV4.5ARSA, Attic insulation shield with ad-

justable height from 12"-22"). See installation

accessories table on Page 30.

E. Support the vertical vent run sections -

Note - Proper venting support is very important.

The weight of the vent must not be supported

by the fireplace in any degree.

Support the vertical portion of the venting

system every 8 feet (2.4m) above the fireplace

vent outlet. One method of support is by utiliz-

ing field provided support straps (conventional

plumber's tape). Secure the plumber's tape to

the framing members with nails or screws.

Loop the tape around the vent, securing the

ends of the tape to the framing. If desired,

sheet metal screws #6 x 1/2" length may be

used to secure the support straps to the vent

pipe. See Figure 17.

B. Attach vent components to appliance

- Secure Vent SV4.5 direct vent system compo-

nents are unitized concentric pipe components

featuring positive twist lock connections (see

Figure 15).

All of the appliances covered in this document

are fitted with collars having locking inclined

channels. The dimpled end of the vent compo-

nents fit over the appliance collar to create the

positive twist lock connection.

Blocking

Support Straps

(Plumber's tape)

8 feet (2.4 m)

Maximum

1 inch (25.4

mm) minimum

clearance to

combustibles

F. Change vent direction to horizontal/inclined

run - At transition from or to a horizontal/in-

clined run, install the SV4.5E45 and SV4.5E90

elbows in the same manner as the straight vent

sections. The elbows feature a twist section to

allow them to be routed about the center axis

of their initial collar section to align with the

required direction of the next vent run element.

Twist elbow sections in a clockwise direction

only so as to avoid the possibility of unlocking

any of the previously connected vent sections.

See

Figure 18.

Figure 18

7-5/8”

(194 mm)

4-13/16

(122 mm)

Swivel Joint

(60° swivel)

SV4.5E45

45° Elbow)

Swivel Joint

(60° swivel)

SV4.5E90

90° Elbow)

(206 mm)

8-1/8"