NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

15

It is important to maintain the required clear-

ances to combustibles: 1" (25 mm) at all sides

for all vertical runs; and " (76 mm) at the top,

1" (25 mm) at sides, and 1" (25 mm) at the

bottom for all horizontal/inclined runs.

H. Frame roof opening - Identify location for

vent at the roof. Cut and/or frame opening per

Roof Framing Chart and

Figure 19.

Figure 20

Figure 19

Figure 22

Figure 21

If the vent system extends more than 5' (1.5

m) above the roof flashing, stabilizers may be

necessary. Additional screws may be used at

section joints for added stability. Guide wires

may be attached to the joint for additional sup-

port on multiple joint configurations.

Framing Dimensions for Roof

Inches (millimeters)

Pitch

C

D

0/12

10-1/2 in.

(267 mm)

10-1/2 in.

(267 mm)

6/12

10-1/2 in.

(267 mm)

12 in.

(05 mm)

12/12

10-1/2 in.

(267 mm)

17 /4 in.

(451 mm)

C

D

Storm

Collar

Flashing

K. Install the vertical termination - The final

step involves installation of the SV4.5CGV-1

Vertical Termination. Extend the vent sections

to the height as shown in the "Vertical vent ter-

mination section" on Page 7. The SV4.5CGV-1

Vertical Termination (Figure 22) installs in the

exact same fashion as any other

Secure Vent

section. Align the termination over the end of

the previously installed section, adjusting the

radial alignment until the four locking dimples

of the termination are aligned with the inlets of

the four incline channels of the last vent section.

Push the termination down until it fully engages,

then twist the termination clockwise running the

dimples down and along the incline channels

until they seat at the end of the channels.

I. Install the roof flashing - Extend the vent

sections through the roof structure. Install the

roof flashing over the vent section and posi-

tion such that the vent column rises vertically

(use carpenters level) (Figure 20). Nail along

perimeter to secure flashing or adjust roofing

to overlap the flashing edges at top and sides

only and trim where necessary. Seal the top

and both sides of the flashing with waterproof

caulking.

J. Install the storm collar - Install the storm

collar, supplied with the flashing, over the

vent/flashing joint. See Figure 21. Loosen

the storm collar screw. Slide collar down until

it meets the top of the flashing. Tighten the ad-

justing screw. Apply non-combustible caulking

or mastic around the circumference of the joint

to provide a water tight seal.