Fireplace framing specifications – Lennox Hearth ADAGIO-MP User Manual

Page 9

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

9

Figure 9 - Framing

FIREPLACE FRAMING SPECIFICATIONS

Figure 10 -

Corner Framing with Square Termination (SV4.5HT-2)

Framing Dimensions - All Models

A

B

C

D

in.

22-1/8

40-1/4

15-/4

44-1/8

mm

562

1022

400

1121

Inches

(millimeters)

C

Back wall of chase/enclosure

(including any finishing materials)

E

D

A

B

7 (178)

Corner Framing Dimensions - All Models

A

B

C

D

E

in.

22-1/8

41-5/8

29-1/2

10

20-7/8

mm

562

1057

749

254

50

Framing With Platform

Inches (mm)

The platform should extend the full width

and depth of the fireplace base.

Top Vent With Horizontal

Termination In A Corner

(MJ) Need review of updated dimen-

sions in tables below (4-17-08)

* D shown here is not

dimensioned to the vertical

center of the horizontal

framing. This is to allow for

the required 4" clearance

above the vent and the 1"

required clearance below

the vent. This does not

include the suggested 1/4"

rise per foot for horizontal

runs.

** With the facade installed

(required - sold sepa-

rately), the appliance base

will need to be elevated a

minimum of /4" above the

floor to allow for the proper

fit of the facade (i.e. use

/4" board minimum as

platform).

u

When installing in a corner configuration, one of

the rear stand-offs will need to be removed.

Step 1. FRAMING

Frame these appliances as illustrated in Figure

9, unless the appliance is to be installed in a

corner.

See

Figure 10 for corner framing installations.

All framing details must allow for a minimum

clearance to combustible framing members as

shown in

Table 6 on Page 6.

If the appliance is to be elevated above floor

level, a solid continuous platform must be

constructed. Headers may be in direct contact

with the appliance top spacers but must not

be supported by them or notched to fit around

them. All construction above the appliance must

be self supporting, DO NOT use the appliance

for structural support.

The fireplace should be secured to the side fram-

ing members using the unit's nailing flanges

on

each side of the fireplace front. See

Figure 8.

Use 8d nails or their equivalent.

Figure 8

Left Side Front Corner of Fireplace Shown

(Right Side Requirements the Same)

Unit Being Secured By Its Nailing

Flanges To The Framing

Frame the opening to the exact dimensions

specified in the framing details in this manual.

Use Top Flange For

5/8” Thick Drywall

Use Center Flange For

1/2” Thick Drywall

Use Bottom Flange

For Flush Mount

D*

B

VENT FRAMING -

TOP VENT WITH ONE

90° ELBOW

Framing should be

constructed of 2x4

or larger lumber

2 x 4 Header must be

installed, vertical as shown

to allow proper clearance

from venting components to

combustible header. See

Figure 50 for more

details.

A

C

Platform

**

Inches (mm)

8

(203)

5-1/8

13-1/8

(333)

10-1/2

(

267

)

(130)

3/4” Minimum from

Finished Floor