22

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Step 4. FIELD WIRING

Caution: Label all wires prior to disconnection

when servicing controls. Wiring errors can

cause improper and dangerous operation.

Verify proper operation after servicing.

Refer to Section A for millivolt appliances and

Section B for electronic appliances. The gas

valve is set in place and pre-wired at the factory

on both models.

A. Millivolt Wiring (See Figure 35)

1. Appliance-mounted ON/OFF burner control

switch (rocker switch) is factory installed

in the control compartment. An optional

wall-mounted switch, wall thermostat, or

one of the optional remote control kits may

also be used.

2. If a wall-mounted ON/OFF control or ther-

mostat is selected mount it in a convenient

location on a wall near the fireplace.

. Wire the control switch within the millivolt

control circuit using the 15 feet of 2 conductor

wire supplied with the unit.

Note: The supplied 15 feet of 2 conductor wire

has one end of each conductor connected to

the gas valve circuit and the other end of each

conductor placed loose inside the bottom

compartment.

Caution: Do Not connect the optional wall

switch to a 120V power supply.

4. If an optional control switch is installed, turn

the appliance-mounted ON/OFF burner control

switch to the OFF position.

ELECTRONIC

WIRING DIAGRAM

JUNCTION BOX

BLK

W

120 V.

24 V.

TRANSF

ELECTRONIC IGNITION

CONTROL BOARD

*WALL MOUNTED ON/OFF SWITCH (OPTIONAL)

OR REMOTE CONTROL RECEIVER

APPLIANCE MOUNTED

ON/OFF SWITCH

PILOT BURNER

IGNITER-SENSOR

ASSEMBLY

GAS VALVE

EV2

EV1

GROUND

CONNECTOR

GREEN LED

WHITE (6)

) 0 2 (

E T I

H W

) 0 2 (

E G

N A R

O

BLACK (20)

) 9 (

E L P

R U P

) 2 1 (

N E

E R

G

BLUE (20)

BLACK (16)

WHITE

FIELD WIRED

FACTORY WIRED

*Turn The Appliance-Mounted ON/OFF Burner Control Switch

To The OFF Position If An Optional Control Switch Is Installed

Optional

Blower

Ground

Figure 35

Figure 36

B. Electronic Wiring (See Figure 36)

Note: The electronic appliance must be con-

nected to the main power supply.

1. Route a 3-wire 120VAC 60Hz 1ph power

supply to the appliance junction box.

2. Remove the electrical inlet cover plate from

the side of the unit by removing the plate's

securing screws. See Figure 11A on Page

10.

. Remove the cover plate's knockout and then

feed the power supply wire through the knock-

out opening and into the unit junction box.

4. Connect the black power supply wire to the

red pigtail lead and the white power supply

wire to the common terminal of the outlet

as shown in Figures 36 and 37.

5. Connect the ground supply wire to the pig-

tail lead attached to outlet's green ground

screw.

6. Appliance-mounted ON/OFF burner control

switch (rocker switch) is factory installed

behind the bottom panel.

Optional wall-mounted switch, wall thermo-

stat, or one of the optional remote control

kits may also be used.

7. If wall-mounted ON/OFF control or thermo-

stat is to be used, mount it in a convenient

location on a wall near the fireplace.

8. If an optional wall-mounted control is to be

used, wire it in the low voltage circuit as

shown in Figure 36.

Note: The supplied 15 feet of 2 conductor wire

has one end of each conductor connected to

the gas valve circuit and the other end of each

conductor placed loose inside the bottom

compartment.

9. If an optional control switch is installed,

turn the appliance-mounted ON/OFF burner

control switch to the OFF position.

10. After the wiring is complete, replace the

cover plate.

OPTIONAL BLOWER KIT

(millivolt models only)

If the blower kit is to be installed at the time of

installation or at a later date, the main power supply

and wall switch must be installed at the time of

installation. This will require that the electrical

connections must be made BEFORE the fireplace

is framed and enclosed in the finished walls.

Route a 3-wire, 120 VAC, 60 Hz, 1 ph power

supply and connect to electrical receptacle wires

and wall switch or wall rheostat.

TP-TH

TP

TH

APPLIANCE- MOUNTED

ON/OFF SWITCH

BK/W(1)

BK/W(1)

WALL-MOUNTED ON/OFF SWITCH (OPTIONAL)

THERMOSTAT (OPTIONAL)

JUNCTION BOx

BLACK

W

GR

120

V

AC

WALL MOUNTED CONFIGURATION FOR FAN SWITCH (OPTIONAL)

BK

R

WIRING DIAGRAM MILLIVOLT GAS VALVES

THERMOPILE

GAS VALVE

FAN

(OPTIONAL)

CAUTION

Ground supply lead must be con-

nected to the wire attached to the

green ground screw located on the

outlet box. See Figure 37. Failure to

do so will result in a potential safety

hazard. The appliance must be

electrically grounded in accordance

with local codes or, in the absence of

local codes, the National Electrical

Code, ANSI/NFPA 70-latest edition.

(In Canada, the current CSA C22-1

Canadian Electrical Code).