Lennox Hearth ADAGIO-MP User Manual

Page 6

Advertising
background image

6

APPLIANCE AND VENT CLEARANCES

The appliance is approved with zero clearance to

combustible materials on all sides (as detailed

in

Table 6), with the following exception: When

the unit is installed with one side flush with a

wall, the wall on the other side of the unit must

not extend beyond the front edge of the unit. In

addition, when the unit is recessed, the side walls

surrounding the unit must not extend beyond

the front edge of the unit. See Figure 1.

12 (305) Mantel

10 (254) Mantel

8 (203) Mantel

6 (152) Mantel

4 (102) Mantel

16

(406)

12

(305)

10

(254)

2 (51) Mantel

Top Of

Appliance

6

(152)

8

(203)

Mantel Clearances

Inches (mm)

14

(356)

Combustible materials

may project beyond the

sides of the fireplace

opening as long as

they are kept within

the shaded areas il-

lustrated here.

At 14" minimum side

wall clearance, a

combustible wall may

project to any length

Figure 4

17"

(432)

14" (356)

Min. Distance to

Unprotected Side Wall

45

°

Combustible Materials Allowed

In Shaded Area “Safe Zone”

2” (51) Minimum

Clearance to Combustibles

12" (305)

5"

(127)

Min. Distance

8-1/4” (210) to

Protected Side Wall

Top View Of

Fireplace

Side

Wall

Side

Wall

inches (millimeters)

Figure 3 - Mantel Clearances - Inches (millimeters)

Side Wall Clearances

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Figure 2 - Minimum Shelf Height Above Fireplace

MODELS

Adagio-MN

Adagio-MP

Adagio-EN

Combustible Shelf Height

Inches (millimeters)

Top Vent - with One 90 Degree Elbow

Secure Vent

Secure Flex (flex elbow)

*52 (121)

*5-/4 (165)

* Includes 4” clearance to combustibles

(required above vent components)

MINIMUM CLEARANCES

Inches (millimeters)

Back

1/2 in. (1 mm)

Sides

1/2 in. (1 mm)**

Top Spacers

0 in. (0 mm)

Floor

0 in. (0 mm)***

From Bottom of Unit

To Ceiling

64 in. (1626 mm)

Vent

 (76)

Top

*

1 (25.4)

Sides & Bottom

SERVICE CLEARANCES

Feet (meters)

Front

 feet (0.9 meters)

Table 6

Do not insulate the

space between the

appliance and the

area above it.

*Shelf Height

(see table)

Shelf Above Fireplace - Top Vent

Drywall

Header

Top Spacers

4”

(102mm)

u

4" clearance is required above the elbow

for installations that require an elbow at the

top of the unit and that ends in a horizontal

termination.

*Note: 3 in. (75 mm) above any horizontal vent
component. See Note

u

in Figure 2.

**Note: See Page 9, Step 1 for clearance

requirements to the nailing flange located at

each side of the unit and any screw heads

adjacent to it.

***Note: To ensure proper fit of the facade

(required - sold separately). The appliance

base will need to be elevated 3/4" minimum

above the floor to allow for the proper fit of the

facade (i.e. use 3/4" board as platform).

SHELF HEIGHT

To provide for the lowest possible shelf sur-

face, the venting attached to the top vent

should be routed in a way to minimize ob-

structions to the space above the appliance.

Do not insulate the space between the appli-

ance and the area above it (see Figure 2).

The minimum height from the base of the ap-

pliance to the underside of combustible ma-

terials used to construct a utility shelf in this

fashion is shown in the table in Figure 2.