Warning – Lennox Hearth ADAGIO-MP User Manual

Page 3

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.



Input (BTU/HR) Manually-Modulated Gas

Valves (millivolt models)

Model

NATURAL GAS

(BTU / HR)

PROPANE GAS

(BTU / HR)

ADAGIO-MN

1,000 high

10,000 low

-------------

ADAGIO-MP

-------------

1,000 high

10,000 low

Table 1

Input (BTU/HR) Electronic Models

Model

NATURAL GAS

(BTU / HR)

PROPANE GAS

(BTU / HR)

ADAGIO-EN

1,000 high

10,000 low

-------------

ADAGIO-EP

if field converted

-------------

1,000 high

10,000 low

Table 2

Burner Orifice Sizes

Elevation 0-4500 feet ( 0-172 meters)

Model

Series

Nat.Gas

drill size (inches)

Propane

drill size (inches)

ADAGIO-MN

#51

-------------

ADAGIO-MP

-------------

#58

ADAGIO-EN

#51

-------------

ADAGIO-EP

if field converted

-------------

#58

Table 5

Electronic Models -

Electronic models have a manually modulated

gas valve. Input of electronic models is shown

in the following table:

These appliances are designed to operate on

natural or propane gas only. The use of other

fuels or combination of fuels will degrade

the performance of this system and may be

dangerous.

Millivolt Models -

Millivolt models come standard with the manu-

ally-modulated gas valve; flame appearance and

heat output can be controlled at the gas valve.
Input of millivolt models is shown in the fol-

lowing table:

Gas Pressure - All Models

Tables 3 and 4 show the appliances' inlet and

manifold gas pressure.

Inlet Gas Supply Pressure

(all models)

Fuel #

Minimum

Maximum

Natural Gas

5.0" WC

(1.24 kPa)

10.5" WC

(2.61 kPa)

Propane

11.0" WC

(2.74 kPa)

1.0" WC

(.2 kPa)

Table 3

Manifold Gas Supply Pressure

(all models)

Fuel #

Low

High

Natural

Gas

(Lo) 2.2" WC

(.55 kPa)

(Hi) .5" WC

(.87 kPa)

Propane (Lo) 6." WC

(1.57 kPa)

(Hi) 10.0" WC

(2.49 kPa)

Table 4

Test gauge connections are provided on the

front of the millivolt and electronic gas control

valve (identified IN for the inlet and OUT for

the manifold side). The control valves have a

3/8" (10 mm) NPT thread inlet and outlet side

of the valve.

These appliances must be isolated from the

gas supply piping system (by closing their

individual manual shut-off valve) during any

pressure testing of the gas supply piping

system at test pressures equal to or

less

than 1/2 psig (3.5 kPa).

These appliances and their individual shut-off

valves must be disconnected from the gas

supply piping system during any pressure

testing of that system at pressures

greater

than 1/2 psig (3.5 kPa).

Orifice Sizes - Sea Level To High Altitude

(All Models)

These appliances are tested and approved for

installation at elevations of 0-4500 feet (0-1372

meters) above sea level, using the standard

burner orifice (See

Table 5). For elevations

above 4500 feet, contact your gas supplier

or qualified service technician. Install the

appliance according to the regulations of the

local authorities having jurisdiction and, in the

USA, the National Fuel Gas Code NFPA 54 /

ANSI Z223.1 - latest edition or , in Canada, the

CAN1-B149.1 and .2 codes - latest edition.

Table 5 shows the gas orifice size required

for the elevations indicated.

WARNING

Propane tanks are at pressures

that will cause damage to valve

components. Verify that the

tanks have step down regulators

to reduce the pressure to safe

levels.

The millivolt appliances are manually controlled

and feature a spark igniter (piezo) that allows the

appliance's pilot gas to be lit without the use of

matches or batteries. This system provides con-

tinued service in the event of a power outage.

Do not use these appliances if any part has

been under water. Immediately call a qualified,

professional service technician to inspect the

appliance and to replace any parts of the control

system and any gas control which have been

under water.

Ne pas se servir de cet appareil s'il a été plongé

dans l'eau, complètement ou en partie. Appeler

un technicien qualifié pour inspecter l'appareil et

remplacer toute partie du système de contrôle

et toute commande qui ont été plongés dans

l'eau.

This appliance is only for use with the type

of gas indicated on the rating plate. This

appliance is not convertible for use with

other gases, unless a certified kit is used.

Cet appareil doit être utilisé uniquement

avec les types de gaz indiqués sur la plaque

signalétique. Ne pas l'utiliser avec d'autres

gaz sauf si un kit de conversion certifié est

installé.

These appliances must not be connected to a

chimney or flue serving a separate solid fuel

burning appliance.

Carbon Monoxide Poisoning: Early signs of

carbon monoxide poisoning are similar to the

flu with headaches, dizziness and/or nausea.

If you have these signs, obtain fresh air im-

mediately. Have the appliance serviced by a

qualified technician as it may not be operating

correctly. Some people are more affected by

carbon monoxide than others. These include

pregnant women, people with heart or lung

disease or anemia, those under the influence

of alcohol, and those at high altitudes.