NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Figure 50 - Burner Flame Appearance

Burner Adjustment

To adjust the flame, move the lever arm up or

down (located in the lower control area as shown

in Figure 51). When the arm is positioned all

the way down it is fully open. When the arm is

positioned all the way up, it is closed.

Ensure that the air shutter is closed (push lever

all the way up).

CAUTION: DO NOT BEND THE AIR SHUTTER

ROD. MAKE SURE THE AIR SHUTTER MOVES

WHEN THE LEVER ARM IS OPERATED.
Observe the flame continuously. If it appears

weak or sooty as previously described, adjust

the air shutter up or down until the flame ap-

pearance is as desired.

The adjustment rod and associated adjustable

air shutter is patented technology. Flame ad-

justments can be made quickly and accurately

to taste without the need of disassembling the

appliance and waiting for 30 minutes after each

adjustment.
When satisfied that the appliance operates

properly, proceed to finish the installation.

Leave the control knob in the ON position and

the burner ON/OFF switch (or optional remote

switch) in the OFF position. Close the lower

control compartment panel.

Note: See Figure 50 for proper burner flame

appearance.

Air Shutter Adjustment Guidelines

• If there is smoke or soot present, first check

the log set positioning to ensure that the

flames are not impinging on any of the logs.

If the log set is properly positioned and a

sooting condition still exists, then the air

shutter opening should be increased.

• The more offsets in the vent system, the larger

the air shutter opening will need to be.

• An appliance operated with the air shutter

opened too far, may have flames that appear

blue and transparent. These weak, blue and

transparent flames are termed anemic.

• Propane models may exhibit flames which

candle or appear stringy. If this is present

and persists, adjust the air shutter to a more

closed position, then operate the appliance

for a few more minutes to ensure that the

flame normalizes and the flames do not

appear sooty.

Figure 51 - Burner Air Shutter

Adjustment

All the way up = CLOSED

All the way down = OPEN

Adjust the rod to the full closed position for

both Natural Gas and Propane. Light the fire-

place, then adjust accordingly after heat-up.

Valve

Front of Burner

Air Shutter

Adjustment

Rod

Reach around the

left side of the

valve to locate

adjustment rod

(JG) Darken the shading in Fig