<VIDEO> (continued)

*1

When the 23/24 Hz mode, 25 Hz (HD, SD) mode, or 50 Hz
(HD, SD) mode is selected in System Menu No. 25 (SYSTEM
FREQ), this item is not displayed.

*2

When the 23/24 Hz mode, 25 Hz (HD, SD) mode, 50 Hz (HD,
SD) mode or 50 Hz mode is selected in System Menu No. 25
(SYSTEM FREQ), this item is not displayed.

The underlining (__) denotes the factory setting mode.

No./Item

Description of setting

689*

1

COMP MODE

This is used to select the method to process the
image compression during recording.

0000 NORMAL

The images are recorded using the regular
compression processing.

0001

DARK

The images are recorded while minimizing the
compressed image distortion which arises in the
dark areas below about 10 IRE (70 mV).

<Notes>
z This setting is valid when recording in the 720p

mode.

z When [DARK] is selected, the indication (c)

blinks to the left of the second line of the super-
imposed indication.

690*

1

UMID REC

This selects whether or not to record the UMID
information on the tape.

0000

OFF

UMID information is not recorded on the tape.
The [EE] output is also blank.

0001

ON

The UMID set in menu No. 691 UMID GEN is
recorded. If no Basic UMID is available in the
input signals, a Basic UMID of the unit, which is
newly generated, is recorded.

<Note>
UMID information cannot be rewritten in this unit.

691*

1

UMID GEN

This selects a UMID that is recorded when
menu No. 690 UMID REC is turned “ON”.

0000

INT

Newly created basic UMID information of this
unit is always recorded.

0001

EXT

The UMID information of the input signals is
recorded. If no UMID is available in the input
signals, a Basic UMID of the unit, which is newly
generated, is recorded.

<Note>
The source pack (of the UMID information) of the
input signal will be recorded on the tape, regardless
of this menu’s setting.

692*

1

UMID
POS

This sets the line on which the UMID
information is to be superimposed.

0000

BLANK

0001

12L

:

:

0006

17L

:

:

0008

19L

<Notes>
z The line selected for the menu item No. 501

VITC POS-1 and No. 502 VITC POS-2 settings
cannot be selected for this item.

z Even if

(RESET) is pressed while the

settings are changed, the settings does not
return to the factory settings.

z Metadata recorded on the tape will be output

giving UMID information first priority. When
metadata is output, set to a line other than the
original multiplexed line or select “BLANK.”

F4

No./Item

Description of setting

693
GAMMA SEL

This selects gamma correction.

0000

OFF

Gamma correction is not carried out.

0001 GAMMA1

This corrects video images shot with the cine
gamma FilmREC mode of the Varicam to images
of film quality (equivalent to Telecine 5 of HD
Gamma Corrector in AJ-GBX27G).

0002 GAMMA2

This corrects video images shot with the cine
gamma FilmREC mode of the Varicam to images
of film quality (equivalent to Telecine 6 of HD
Gamma Corrector in AJ-GBX27G).

0003 GAMMA3

This converts video images shot with the cine
gamma FilmREC mode of the Varicam into the
Cineon curve appropriate for film recording.

<Notes>
z Gamma correction is effective in the following

conditions.
Š When the VTR operation mode is VV (TAPE)

and 720p is displayed in the system format.

However, when the 23/24 mode is selected in
System Menu No. 25 (SYSTEM FREQ), or 59/
60 and 50i/25p are selected in System Menu
No. 25 (SYSTEM FREQ), as well as performing
the cross conversion from 720p to 1080i,
gamma correction is not performed for SD
output.

z If it is set to execute gamma correction, the GM

indicator in the time code display lights
constantly.

z When the power of the unit is turned OFF, the

settings in this item also return to [OFF].

z This item is not effective for 1394 output.

256

256

512

512

768

768

1023

1023

TELECINE5

TELECINE6

Cineon

Advertising