Registering TCG values

1

Selecting the values
Press the

TC/CTL button to select TC.

Press the

button. The selected item (cue time or TC)

is now highlighted.
Turn the ADJUST dial to select TC.
Again press the

button. A single digit is highlighted,

and the mode for inputting numerical values is
established.

<Notes>

zThe UBG value and cue time can be registered in the

same way. The CTL value cannot be registered.

zTC or UB can be registered only when the internal time

code generator has been selected.

2

Inputting numbers and letters
Press the

to

number keys to input numerical

values.
Use the

and

buttons to input A, B and C, and the

and

buttons to input D, E and F.

To move the input digit, turn the ADJUST dial.
To input a minus sign, press the

and TRIM– buttons

when the left-most digit is highlighted.
To input a “plus” symbol, press

and the TRIM+ button

or press

when the digit to the far left is inverted. (The

display goes blank.)
To clear all the digits to zero, press the

and

buttons.
<Notes>
z Every time when the

button is pressed while

pressing the

button, the display changes in the

following sequence: A

> B > C > A > B and so

on.
The same applies when D, E and F are input using

and

.

z If, when “REV” has been selected as the setup menu

item No.144 (TC INPUT) setting, the

button is

released while a letter is being input, the displayed
character will be entered.

z Letters can be input only while a UBG value is being

registered.

z The input of a minus number is possible only while

the cue time is being registered after “

d12h” is

selected as the setup menu No.002 (TAPE TIMER)
setting and CTL is selected by the

TC/CTL

button.

z If “REV” has been selected as the setup menu item

No.144 (TC INPUT) setting, the input starts from the
highest order digit (the display appears from the far
right). However, turning the ADJUST dial once will
restore the NORMAL input mode.

3

Entering the input values
Press the

button. The value input is registered,

and the normal display is restored.

<Notes>
z To cancel the registration, press the

button.

z If the input value is outside the registration enable

range, the

alarm blinks, and the value

cannot be registered until it has been corrected.

F3

T

T

0

9

F

7

F

8

F

F

0

F

0

7

F

F

8

F

F3

ENT

C

INVALID

Advertising