Return to alarm mode status, Alarm suspension, Alarm history display – Panasonic WJ-SX650 User Manual

Page 69: Wv-cu360c/cj, Details on alarm history display

Advertising
background image

69

Notes:

• Alarm all reset will also be conducted when setting

changes are performed in SETUP MENU or WJ-SX650
Series Administrator Console.

• To reset the alarms occurred to recorders, perform

alarm all reset. Alarm all reset is available even while no
alarms are occurring.

■ Return to Alarm Mode Status

You can recover from the ACK status to the alarm mode
status.

● WV-CU950/650

Press the ACK button while holding down the SHIFT button.
The alarm mode will be recovered.

● WV-CU360C/CJ

This operation is not available.

■ Alarm Suspension

You can suspend the unit from accepting alarm input sig-
nals when you do not want to be disturbed.

1. Press the ALM SUSPEND*

1

(or SUSPEND*

2

) button

while holding down the SHIFT button.
The alarm will be suspended.
*

1

WV-CU950/650

*

2

WV-CU360C/CJ

2. To cancel the alarm suspension mode, press the ALM

SUSPEND button while holding down the SHIFT button
again.

■ Alarm History Display

The latest 1 000 alarm records (date, time and details) can
be displayed as the alarm history on an active monitor.

Note: Alarm History Display is not available on monitors in

the alarm mode or during recorder selection.

● WV-CU950/650

Press the ALM RECALL button. The Alarm History Display
will appear on the selected monitor.

● WV-CU360C/CJ

Press the OSD and ALM H buttons at a time. The Alarm
History Display will appear on the selected monitor.

● Details on Alarm History Display

"

∗" beside the time indicates daylight saving time (sum-

mer time).

The following items are display details.

• ALARM (Highlighted for reset alarms)

T-001 to 256: Terminal alarm

(Example: For T-001, "001" means the number of
alarm input signal accepted by the ALARM IN port
of video input board.)

C-001 to 999: Camera alarm

(Example: For C-001, "001" means the number of
camera supplying an alarm input signal to the unit.)

R-001 to 999: Recorder alarm

(Example: For R-001, "001" means the number of
camera associated with the recorder supplying an
alarm input signal to the unit.)

S-0001 to 1024: Serial alarm

(Example: For S-0001, "0001" means the serial com-
mand alarm input number.)

V-001 to 999: Video loss

(Example: For V-001, "001" means the number of
camera to which video loss has occurred)

ALL:

Alarm all reset

: Alarm suspension ON/OFF

• ACTION

POWER: The unit is powered on. (Highlighted: Power

off)

M01 to 32: Alarm occurred to Monitor 1 to 32. (For

group sequence and group preset, the smallest
monitor number is displayed with "

∗".)

C001 to C999: Camera 001 to Camera 999 was activat-

ed for spot mode.

S

ALARM HISTORY 1 of 100
M D Y H M S ALARM ACTION REC
Aug31/06

∗11:59:00PM ALL 12345 K4-8

Aug31/06

∗11:58:00PM C-999 M32 C100 001

Aug31/06

∗11:57:00PM V-001 M03 T32 256

Aug31/06

∗11:56:00PM POWER

Apr15/05

∗09:15:25AM POWER

Apr15/05

∗09:15:25AM R-003

Apr15/05

∗09:13:54AM S-0002 M10*G32 ———

Apr15/05

∗09:12:32AM T-001 M20 ——— 999

Jan02/05 03:05:10PM S 6789 PC
Jan01/05 03:04:08PM S 101 PSD
T-TERMINAL C-CAMERA R-RECORDER
S-SERIAL V-VIDEO LOSS SSUSPEND