Connections of Matrix Switchers (WJ-SX650 Series) and a PS·Data

System Controller

By setting the DATA ports of matrix switchers to PSD in SETUP MENU (refer to p.

90

) and connecting a PS·Data system con-

troller (

CONTROLLER NO.: 1

) to one of the ports, you can control these units from the system controller. (Refer to p.

69

for

details on connections.)
By connecting a PS·Data system controller (CONTROLLER NO.: 1) to the DATA ports of the units with Cable Kit WV-CA48/10K,
you can control these units from the system controller. (Refer to p.

69

for details on connections.)

Notes:

• Connect Cable Kit to the DATA 1 port.
• Set the DATA 1 port of each unit to PSD. (Refer to p.

90

.)

Connections and Operations

• When controlling two or more units from a PS·Data system controller, you need to select a unit before operation. Refer to

WV-CU950/650 Operating Instructions for system unit selection.

• The unit address of each unit must be different from that of system controller.

The unit address settings are performed in

"Communication" – "PS·Data" of WJ-SX650 Series Administrator Console.

• When an alarm occurs to a unit, other units will accept the alarm as a serial alarm input.

User level settings for alarm suspension must be the same within all the units. If alarm suspension is restricted in the level
setting of a unit, operators with the restricted levels cannot suspend even alarms occurring to other units.

The LCD settings are performed in "System" – "Logical Camera Number" of WJ-SX650 Series Administrator Console. Up to
LCN 999 are available for the settings.

Controlling from a Web Browser Accessing a Recorder

If a recorder is connected to the unit, you can control cameras using a web browser installed on a PC accessing the recorder.
You can set priority for web browser control. Priority setting is performed in "Operator" – "Operator" of WJ-SX650 Series
Administrator Console.

Notes:

• Refer to the operating instructions of recorder for details on browser control.
• Regardless of priority setting, during the recorder control from a system controller, camera control is not available from a

web browser accessing recorders connected to the same DATA port in the daisy chain.

Controlling from a PC

You can perform the operations and functions of system controllers by logging into the system and sending RS-232C com-
mands from a PC connected to the unit. Refer to Serial (RS-232C) Connector Command Reference (PDF file on the supplied
CD-ROM) for available commands.

Matrix Switcher WJ-SX

650

Matrix Switcher WJ-SX

650

Matrix Switcher WJ-SX

650

A

B

1

3

2

4

6

5

7

9

8

0

SYSTEM CONTROLLER

OPERATE

OPERATE LED WILL BLINK

IF COOLING FAN MALFUNCTIONS

OPERATE

OPERATE LED WILL BLINK

IF COOLING FAN MALFUNCTIONS

Cable Kit

WV-CA48/10K

CONTROLLER NO.: 1

Unit Address: 1

Unit Address: 2

Unit Address: 3

OPERATE

OPERATE LED WILL BLINK

IF COOLING FAN MALFUNCTIONS

Advertising