background image

Connections

With the power to the DA7 off, insert two optional ADAT cards into

SLOT 1

and

SLOT 2. Carefully screw these cards into their respective slots in the

DA7 so they are properly grounded. Each ADAT machine is connected to an
option card via two optical cables, one In and one Out. The 8-track ADAT
signal in

SLOT 1 is assigned to inputs 17-24, and the 8-track ADAT signal in

SLOT 2 is assigned to inputs 25-32.

The output sources into the ADAT can be selected from the

[D-I/O>SLOT

OUT] window.

Refer to Chapter 12, D-I/O for additional information.

Wordclock Setup

The Word Clock master is the ADAT connected to

SLOT 1, and the ID setting

must be set to zero. From the

[D-I/O>INPUT SET] window scroll to SLOT 1

and select it as the Word Clock master source. This will tell the DA7 that the
device in

SLOT 1 is the Word Clock master.

ADAT + BRC + DA7

This diagram shows how to connected an ADAT and a BRC Clock master to
the DA7.

To verify that the setup is properly connected, go to the

[D-I/O>INPUT SET]

window. On the lower left, where

SLOT 1, SLOT 2, and SLOT 3 are

indicated, the crosshatching will go away when a proper connection has
been made.

C h a p t e r 1 7

D A 7 U s e r s ’ G u i d e

17

-

3

17

Options

ADAT + BRC + DAT GRAPHIC

ADAT ID2

ADAT ID1

SYNC IN

SYNC OUT

OUT

OUT

OUT

IN

IN

IN

IN OUT

SYNC IN

SYNC OUT

WCK master

SMPTE IN

EFX Device

DAT

S/PDIF/ I/O

AES/EBU I/O

WR-

ADAT

WR-

ADAT

DA7

TO PC

CR monitor out

PC

Power amp

SP

SP

WCK OUT

WR-

SMPTE

WCK IN

BRC ID 0