Format Select Switch

This switch is used to select the signal format of the

Digital Record Output,

either

AES/EBU (RS-422/110

Ω

) or

S/PDIF (0.5 V[p-p]/ 75

Ω

) physically. The

status information included in the output signals is always “professional”
regardless of the switch position.
For S/PDIF usage, an optional adapter is required(Part No. DA/ADPTF). You
must make certain that the adapter connects pin #1 and #3 together.

Clock Terminating 75 ½ ON/OFF & Out / Thru Switch

Located next to the

WORD CLOCK IN BNC connection, this switch should

be set to 75

Ω

OFF and Thru position if the DA7 is being used to pass the

wordclock signal to other devices in the chain.

Set the switch to 75

Ω

ON and OUT for terminating the wordclock, if the

DA7 is slaved and located at the end of the wordclock chain. The 75

Ω

ON

and

OUT position should also be selected when the DA7 is being used to

slave other devices to the DA7’s wordclock. See Chapter 12, D-I/O for more
information.

Clock Input

This is used to synchronize the DA7 to an external wordclock source. This
allows the DA7’s internal clock to slave to another reference, such as a digital
multi-track deck or other device. Use a BNC connector to attach an external
wordclock source.

Clock Output

This is used to slave an external device, such as a digital multi-track machine,
to the DA7 internal clock. It can also be used to relay an external wordclock
that is being used to synchronize the DA7 to an external device. Using a BNC
connector, other devices can synchronize to the DA7 wordclock.

Serial Terminating Switch

Set the switch to

ON if the DA7 is the termination point of the RS-422/485

serial transmission path. The 110

Ω

switch turns this function

OFF/ON.