Error messages

Display

• Description
• VTR operation and remedial action

T REEL
TORQUE ERR

If an abnormal torque applied to the take-up reel motor
is detected, the AUTO OFF lamp lights, and the
message display blinks.
VTR: Stops.
• Set the POWER switch to OFF and then back to ON

again.

S REEL
TORQUE ERR

If an abnormal torque applied to the supply reel motor
is detected or if an abnormal current flowing to the
current-sensing resistor is detected, the AUTO OFF
lamp lights, and the message display blinks.
VTR: Stops.
• Set the POWER switch to OFF and then back to ON

again.

If the error message display persists even after the
VTR has been shut down and started up again,
consult your dealer.

UNLOAD
ERROR

If the tape has not been wound up during unloading,
the AUTO OFF lamp lights, and the message display
blinks.
VTR: Stops.
• Set the POWER switch to OFF and then back to ON

again.

WINDUP
ERROR

If, after the total tape amount has been detected, the
amount of tape wound up onto the take-up reel and the
amount of tape supplied by the supply reel differ to an
abnormal extent while the tape is traveling, the AUTO
OFF lamp lights, and the message display blinks.
VTR: Stops.
• Set the POWER switch to OFF and then back to ON

again.

W-UP REEL
NOT ROTA

If, after the cassette has been inserted, the tape take-
up reel has not wound up the tape while the total tape
amount is not detected and while the tape is traveling,
the AUTO OFF lamp lights, and the message display
blinks.
VTR: Stops.
• Set the POWER switch to OFF and then back to ON

again.

Error messages

S-FF/REW
TIMEOVER

When the tape start or end processing operation is not
completed, the AUTO OFF lamp lights, and the
message display blinks.
VTR: Stops.
• Set the POWER switch to OFF and then back to ON

again.

T REEL ROTA
TOO FAST

If the take-up reel motor rotates at an abnormally fast
rate, the AUTO OFF lamp lights, and the message
display blinks.
VTR: Stops.
• Set the POWER switch to OFF and then back to ON

again.

S REEL ROTA
TOO FAST

If the supply reel motor rotates at an abnormally fast
rate, the AUTO OFF lamp lights, and the message
display blinks.
VTR: Stops.
• Set the POWER switch to OFF and then back to ON

again.

Display

• Description
• VTR operation and remedial action

FRONT LOAD
MOTOR

If the cassette fails to move up even after 6 seconds
have elapsed since the VTR transferred to the EJECT
mode, the AUTO OFF lamp lights, and the message
display blinks.
<Note>
If the cassette fails to move down even after 6 seconds
have elapsed since the cassette was inserted, the VTR
transfers to the EJECT mode.
VTR: Stops.
• Set the POWER switch to OFF and then back to ON

again.

LOADING
MOTOR

If the unloading operation fails to be completed within 6
seconds, the AUTO OFF lamp lights, and the message
display blinks.
<Note>
If the loading operation fails to be completed within 6
seconds, the VTR transfers to the EJECT mode
(unloading mode).
VTR: Stops.
• Set the POWER switch to OFF and then back to ON

again.

REEL DIR
UNMATCH

If the take-up reel motor is running in the reverse
direction, the AUTO OFF lamp lights, and the message
display blinks.
VTR: Stops.
• Set the POWER switch to OFF and then back to ON

again.

REEL
TENSION
ERROR

If an abnormal tension at the supply side is detected in
the reel mode, the AUTO OFF lamp lights, and the
message display blinks.
VTR: Stops.
• Set the POWER switch to OFF and then back to ON

again.

SERVO COMM
ERROR

When the servo microcomputer does not follow the
instructions of the system control microcomputer even
after 10 seconds have elapsed, the AUTO OFF lamp
lights, and the message display blinks.
VTR: Stops.
• Set the POWER switch to OFF and then back to ON

again.

SERVO
CONTROL
ERROR

When there is no response from the servo
microcomputer for 1 or more seconds, the AUTO OFF
lamp lights, and the message display blinks.
VTR: Stops.
• Set the POWER switch to OFF and then back to ON

again.

SERVO
ERROR

When only the servo microcomputer was reset in an
instantaneous power failure, etc., the AUTO OFF lamp
lights, and the message display blinks.
VTR: Stops.
• Set the POWER switch to OFF and then back to ON

again.