Output Signal Table Objects

The Output Signal Table contains entries for the output signals that can be
asserted by the unit, for the synchronous User Data port. Clarification for objects
contained in this table as it applies to the unit is provided in

Table C-12

.

Table C-12.

Output Signal Table Objects

Object

Description

Setting/Contents

rs232OutSigName
(rs232OutSigEntry 2 )

Contains the identification
of a hardware output signal.

Supports only the following
values:

cts(2) – Clear To Send

dsr(3) – Data Set Ready

dcd(6) – Received Line Signal
Detector

rs232OutSigState
(rs232OutSigEntry 3 )

Contains the current signal
state.

Supports only the following
values:

on(2) – The signal is asserted

off(3) – The signal is deasserted

rs232OutSigChanges
(rs232OutSigEntry 4 )

Indicates the number of
times that a signal has
changed from on to off, or
off to on.

Increments the object each time
that the signal is sampled (every
100 ms) and the signal state is
different from the previous state.

Ethernet-Like MIB, RFC 1643

The unit supports the Ethernet-Like MIB, RFC 1643 for all objects

except :

H

dot3TestTdr, and

H

dot3StatsEtherChipSet

Enterprise MIB

The following Paradyne Enterprise MIB Objects are supported by the unit:

H

Device Configuration Variable (pdn-dev Config 7)

H

Port Usage Table, pdn-devPortUsage (pdn-interfaces 3)

H

DDS Interface Specific Definitions, pdn-dds (pdn-interfaces 2)

H

Device Security, pdn-security (pdn-common 8)

H

Device Traps, pdn-traps pdn-common 9)

H

Device Control, pdn-control (pdn-common 10)