Monitoring the DSU

6-7

7612-A2-GB20-10

November 1997

The following messages appear in the first column of the System and Test Status
screen. The messages are listed from high to low priority on the screen but in
alphabetical order in Table 6-1. The highest priority Health and Status message
also appears on the bottom right of all ATI screens.

Table 6-1.

Health and Status Messages (1 of 2)

Message

What Message Indicates

What To Do

Cross Pair
Detection

The DDS Receive (RX) and
Transmit (TX) pairs are
crossed on the network
interface. Alarm LED is on.

Reverse the RX and TX pair at the
punchdown block or other
termination point.

Device Fail
yyyyyyyy

An internal error has been
detected by the operating
software.

yyyyyyyy indicates

the 8-digit hexadecimal failure
code.

1. Provide the 8-digit failure code

shown (

yyyyyyyy ) to your service

representative.

2. Use the Clear command to clear

the message.

3. Reset the DSU to clear the

condition and message.

DSU Operational

The DSU is functioning
properly and there are no
status messages to display.

No action required.

Ethernet Link
Down

The DSU detects no electrical
activity on the 10BaseT port.

1. Verify that the Ethernet cable is

securely attached at both ends.

2. Contact your LAN support

technician if problem persists.

Excessive BPVs
hhh:mm:ss

1

Data rates do not match or
network trouble causing
bipolar violations. Alarm LED
is on and Network
Performance Statistics are
active.

1. Verify that the network cable is

securely attached at both ends.

2. Contact network provider if

problem persists.

3. Check line rate.

In-Band Fram Err
hhh:mm:ss

1

The IMC communication
between the local and remote
DSU is not working.

1. Verify that the remote unit has

IMC set at the same rate.

2. Contact network provider if

problem persists.

In-Band Mgmt
Channel Fail

The IMC is not operational.

Enable the IMC on the remote unit.

No Signal
hhh:mm:ss

1

No signal is being received.
Local DSU network problem.
The Alarm and NS LEDs are
on and Network Performance
Statistics are active.

1. Verify that the network cable is

securely attached at both ends.

2. Contact network provider.

1

hhh:mm:ss indicates the amount of time the condition has existed in hours, minutes,
and seconds. When the maximum time has been exceeded, 255:59:59+ appears.