Paradyne 7612 SNMP DSU User Manual

Page 60

Advertising
background image

Testing

7-9

7612-A2-GB20-10

November 1997

4. Tab to the desired option, and enter yes (or y) for the selected prompt.

If entering yes to prompt . . .

Then all . . .

Reset Terminal Port Options

Terminal port options are set to their factory
default values. Refer to Table A-5,

Terminal Port

Options

.

Reload Factory Defaults

Factory default settings contained in the Default
Factory Configuration area are loaded in Current,
Customer 1, and Customer 2 configuration areas.

Any changes to configuration and control settings
will be replaced by the factory defaults.

If no (or n) is entered, or if no selection is made within 30 seconds, the DSU
returns to the condition or operation it was in when the system pause was
initiated, with the Terminal port data rate returning to its configured rate.

5. If yes (or y) is entered, the DSU resets itself and initiates a Device Self-Test.

Connectivity is restored and the User Interface Idle screen appears.