Configuration Option Tables

A-4

7612-A2-GB20-10

November 1997

Table A-1.

System Options (3 of 3)

Test Timeout

Possible Settings: Enable, Disable
Default Setting: Enable

Allows user-initiated tests to end automatically. Recommend enabling when the unit is
managed remotely through the IMC to avoid the requirement to terminate the test
manually.

Enable – User-initiated loopback and pattern tests end when test duration is reached.

Disable – Tests can be terminated manually from the Network Tests screen. Refer to

Network Tests

in Chapter 7.

NOTE:

Tests initiated by the DTE or network are not affected by this test timeout.

Test Duration (min)

Possible Settings: 1–120
Default Setting: 10

Number of minutes for a test to be active before automatically ending.

H

Test Duration (min) option appears when Test Timeout is enabled.

1 to 120 – Amount of time in minutes for a user-initiated test to run before terminating.