Self-test results, Able 6-2, Self-test results messages – Paradyne 7612 SNMP DSU User Manual

Page 45

Advertising
background image

Monitoring the DSU

6-8

7612-A2-GB20-10

November 1997

Table 6-1.

Health and Status Messages (2 of 2)

Message

What To Do

What Message Indicates

Out of Frame
hhh:mm:ss

1

DSU is detecting an out of
frame condition, associated
with:

H

Receiving out of frame
code from the network.

H

DSU detecting out of frame
errors with 64 kbps CC
data rate.

H

DSU unable to synchronize
local receiver circuit with
line signal.

1. Verify that the line rate matches

the configured rate.

2. Contact network provider.

Out of Service
hhh:mm:ss

1

DSU is receiving out of
service code from the
network for the remote unit.
The Alarm and OOS LEDs
are on and Network
Performance Statistics are
active.

1. Verify that the remote site is in

service.

2. Contact network provider.

User Data Port
DTR Off

The DTE is not ready to
transmit or receive data. This
message will not appear
unless Monitor DTR is
enabled.

1. Check on the DTE status. Verify

that the DTE is powered up and
asserting DTR.

2. Disable Monitor DTR.

1

hhh:mm:ss indicates the amount of time the condition has existed in hours, minutes,
and seconds. When the maximum time has been exceeded, 255:59:59+ appears.

Self-Test Results

The results of the last power-up or reset self-test appear in the middle column of
the System and Test Status screen.

Table 6-2.

Self-Test Results Messages

Message

What Message Indicates

What To Do

Device Fail

One or more of the DSU’s integrated
circuit chips has failed device-level
testing.

1. Reset the DSU and try again.

2. Use the Clear command to

clear the message.

3 Call your service

Memory Fail

DSU failed memory verification.

3. Call your service

representative for assistance if
the message reappears.

Passed

The DSU has been plugged in or
reset and has passed the diagnostic
test. There are no other status
messages.

No action required.

Advertising