Connection with the Camera

Site

System Camera Connection

Connect system cameras to VIDEO IN 5-8.

Data-multiplex Camera Connection

Connect combination cameras directly to VIDEO IN 1-4.
When connecting to VIDEO IN 5-8, use a Data Multiplex
Unit as shown below.

Connection with the Monitors

Connect the spot and multiscreen monitors.

ALARM/REMOTE Connection

A 25-pin connector is used to accept and supply control
signals.

4

4

5

5

6

6

7

7

8

8

OUT

VIDEO

IN

DATA

RS485 Cable

POWER

ON

OFF

ALARM

Data Multiplex Unit WJ-MP204

ALARM

SUSPEND

Combination Cameras

Pan/Tilt Table

Receiver

Data Multiplex
Unit

6

6

7

7

8

8

OUT

IN

ON

OFF

POWER

ON

OFF

POWER

Spot Monitor

Multiscreen Monitor

Disk Recorder

WJ-HD220

MULTI

SCREEN OUT

SPOT

OUT

Pin

#

1

13

14

25

ALARM/REMOTE

Designation

1

2

3

4

5

6

7

8

9

10

11

12

13

Alarm Reset In

Alarm In 1

Alarm In 2

Alarm Recovery Out *1

Alarm Recovery Out 2

Alarm Out 1

Alarm Out 2 *2

Disk End Out

Warning Out

Alarm In 3

Alarm In 4

REC Status Out

Time Adjust In

Pin

#

14

15

16

17

18

19

20

21

22

23

24

25

Designation

Time Adjust Out

Alarm In 5

Alarm In 6

Alarm In 7

Alarm In 8

Signal GND

Signal GND

Play Status Out

EXT REC MODE In

No Connection

Sequence In

Sequence Out