Notes:

• Input rating: Low-active, non-voltage normally open (N.O.) contact
• Output rating for pin #4 Alarm Recovery Out

*1

: High-active with a 200

Ω resistor pulled up to +5 V

• Output rating for pin #7 Alarm Out 2

*2

: High-active with a 4.7 k

Ω resistor pulled up to +12 V

• Output rating for pin #6 Alarm Out 1: Low-active, maximum load capacity of +12 V 100 mA
• Output rating for other pins: Low-active, maximum load capacity of 24 V 100 mA , open-collector with a 4.7 k

Ω resistor

pulled up to +5 V inside

• Pin #24 Sequence In receives a close contact input to advance the sequence one step. This input does not start a

sequence but forwards the presently running sequence by one step.

• Pin #25 Sequence Out supplies a negative pulse when the sequence running on the multiscreen monitor advances one

step.

Alarm Connection

There are eight alarm inputs, while two outputs are provided with different driving capacity.

External Recording Connection

The recording mode will change from the internal timer
mode to the external mode (EXT REC MODE) specified in
REC SETUP menu when the switch is turned on.

Time Adjusting Connection

The internal timer is calibrated with this input.

Sensor

Door Switch

Alarm Input Terminals

Signal Ground Terminals

#7 Alarm Out 2 *2

External
Alarm
Reset Switch

#2 Alar

m In 1

#3 Alar

m In 2

Relay *1

Alarm Indicator

*1: Use when the indicator exceeds over the drive capacity of the alarm out terminal.
*2: Connect to #6 Alarm Out 1 when using a low-active device.

Master Clock

Non-voltage N.O. contact
N.O.=Normally Open

#13

Time Adjust In

#22 External Recording Mode