Setup Control

Item

Transmission Command (ASCII)

Response (ASCII)

Parameter (ASCII)

Cursor Moves

DCR:n1n2

DCR

n1=A Right
n1=C Upward
n1=E Left
n1=G Downward
n2=1 Move a step
n2=2 Move multi steps
n1n2=PD Move to lower layer
n1n2=P+ Move to upper layer
n1n2=P- Turn a newer page
n1n2=PU Turn an older page

Key Lock

MKL:n

MKL

n=0 Lock OFF
n=1 Lock ON

Recording Event

MRM:n

MRM

n=0 Normal recording

Setup

n=1 Internal timer recording
n=2 External timer recording

Summer Time Setup

MST:n

MST

n=0 Standard time
n=1 Summer time

Setup

MSU:n

MSU:n

n=0 End setup
n=1 Begin setup

Date&Time Setup

TSU:yyyymmddhhnn

TSU

yyyy=Year
mm=Month
dd=Day
hh=Hour (24-hour system)
nn=Minute

Miscellaneous Control

Item

Transmission Command (ASCII)

Response (ASCII)

Parameter (ASCII)

OSD Show/Hide

DIN:n

DIN

n=+ Toggle
n=0 Hidden
n=1 Shown

Communication Check RCK

RCK

Time&Date Search

ZTS:yyyymmddhhnnss

ZTS

yyyy=Year
mm=Month
dd=Day
hh=Hour (24-hour system)
nn=Minute
ss=Second

Time&Date

ZTL:n

ZTL

n=7 Search window displayed

Search Window

n=0 Search window hidden

Alarm Log

ZTM:n

ZTM

n=1 Alarm log search displayed

Search Window

n=0 Alarm log search hidden

Data Log Control

Item

Transmission Command (ASCII)

Response (ASCII)

Parameter (ASCII)

Log Total Size Inquiry

ILB:k

ILB:k:bbbbb

k=0 Alarm log
bbbbb=00001 to 09999 (in decimal)

Log Erase

ILC:n

ILC:n

n=0 Alarm log
n=1 System log

Log Recorded

ILQ:k

ILQ:k:bbbbb:ddddd:(:E)

k=0 Alarm log

Size Inquiry

bbbbb=00001 - 09999 (Oldest log)
ddddd=00001 - 09999 (Size of log)
E=Overwrite

Log Readout

ILR:k:sssss:mmmmm

ILR:k:<log data s1>s1

k=0 Alarm log

<log data s2>s2

sssss=00001 - 09999 Start Address

<log data sn>F

mmmmm=00001-00100

Decimal # of log

<log data sn>=yymmddhhnnss
sn=0-9 and F