Baud rate (baud rate), Data bit (data bit), Parity check (parity check) – Panasonic WJ-HD220 User Manual

Page 39: Stop bit (stop bit), Wait time (wait time), Data)

Advertising
background image

39

PS

DATA: Select when the communication chain uses

the PS

DATA protocol.

This selection enables the DATA terminal on the
rear panel for communication.

RS-232C: Select when a protocol other than PS

DATA

is used.
This selection enables the RS-232C terminal on the
rear panel for communication.

Note: Parallel use of the DATA and RS-232C terminals

is not possible.

Baud Rate (BAUD RATE)

1. Move the cursor to BAUD RATE with the [D] or [C] but-

ton.

2. Select the rate with the JogDial, and press the JogDial.

The default value is 9600 bits per second.

4800: 4 800 bps
9600: 9 600 bps*
19200: 19 200 bps

Data Bit (DATA BIT)

1. Move the cursor to DATA BIT with the [D] or [C] but-

ton.

2. Select the bit length with the JogDial.

The default value is 8 bits.

7: 7 bits* ; select when using RS-232C protocol.
8: 8 bits

Parity Check (PARITY CHECK)

1. Move the cursor to PARITY CHECK with the [D] or [C]

button.

2. Select the check mode with the JogDial.

The default is NONE.

NONE: No parity check
EVEN: Even parity
ODD: Odd parity*

Stop Bit (STOP BIT)

1. Move the cursor to STOP BIT with the [D] or [C] but-

ton.

2. Select the number of stop bits with the JogDial.

The default is 1.

1: 1 bit*
2: 2 bits

Wait Time (WAIT TIME)

The unit retransmits data after waiting the specified time if
there is no response from the connected device.

1. Move the cursor to WAIT TIME with the [D] or [C] but-

ton.

2. Select the waiting time with the JogDial.

The default is OFF.

OFF: Retransmission is disabled. *
100MS: 100 m seconds
200MS: 200 m seconds
1S: 1 second

Control Unit Address (CTL-UNIT

ADDRESS) (only for PS

DATA)

When the recorder performs as a controller in the system,
the unit address can be set from the setup menu on the
monitor.

1. Move the cursor to CTL-UNIT ADDRESS with the [D] or

[C] button.

2. Select the address with the JogDial.

The default value is 1.

Assignable address: From 1 to 99, must be unique in

the chain.

Note: Assign an address except 1 to WJ-HD220 when

using a system controller in the system.

System Unit Address (SYS-UNIT

ADDRESS) (exclusive to PS

DATA)

When the recorder performs as a system unit, the unit
address can be set from the setup menu on the monitor.

1. Move the cursor to SYS-UNIT ADDRESS with the [D] or

[C] button.

2. Select the address with the JogDial.

The default value is 1.

Assignable address: From 1 to 99, must be unique in

the chain.