National Instruments 800 Series User Manual

Page 27

Advertising
background image

Chapter 3

VXIpc 800 Series Configuration and Installation

© National Instruments Corporation

3-3

VXIpc 800 Series User Manual

Table 3-1 lists the factory-default settings and options for the onboard
jumpers and switches.

Table 3-1. VXIpc 800 Series Hardware Default Settings

Jumper/

Switch

Default

Setting

Optional

Setting

W1

Supply SCSI termination
power

Disable SCSI termination

W2

Normal CMOS operation

Clear CMOS

W4

LPT1 uses DMA Channel 1

LPT uses DMA Channel 3

W13

Enable automatic Slot 0
detection

Force Slot 0;
Force Non-Slot 0

S1

Enable Ethernet EEPROM
configuration

Disable Ethernet EEPROM
configuration (uses default
power on values)

S2

Enable MITE
self-configuration

Disable MITE
self-configuration

S3

Source CLK10 from
onboard oscillator

Source CLK10 from SMB

S4

Non-inverted CLK10
output

Inverted CLK10 output

S5

Receive CLK10 input from
SMB

Source CLK10 output to
SMB

S6

No termination on CLK10
input

Terminate CLK10 input
to 50

S7

No termination on external
trigger input

Terminate external trigger
input to 50

S8

GPIB uses IRQ11

GPIB uses IRQ5

S9

MITE user configuration

MITE factory configuration

Advertising