Environmental, Vmebus capability codes – National Instruments 800 Series User Manual

Page 42

Advertising
background image

Appendix A

Specifications

© National Instruments Corporation

A-3

VXIpc 800 Series User Manual

Environmental

Note:

Random vibration profiles were developed in accordance with
MIL-T-28800E and MIL-STD-810E Method 514. Test levels exceed
those recommended in MIL-STD-810E for Category 1 (Basic
Transportation, Figures 514.4-1 through 514.4-3). Test report
available upon request.

VMEbus Capability Codes

Characteristic

Specification

Temperature

0

°

to 55

°

C Operating;

-20

°

to 70

°

C Storage

Relative
Humidity

0% to 95% Noncondensing, Operating;
0% to 95% Noncondensing, Storage

EMI

FCC Class A Verified, EC Verified

Vibration

Operational: 5 to 500 Hz, 0.31 g, 3 axes
Non-operational: 5 to 500 Hz, 2.5 g, 3 axes

Functional Shock

MIL-T-28800E Class 3 (per Section 4.5.5.4.1)
Half-Sine Shock Pulse (11 ms duration, 30 g peak,
3 shocks per face)

Capability Code

Description

A32, A24, A16 (master)

VMEbus master A32, A24, and A16
addressing

A32, A24, A16 (slave)

VMEbus slave A32, A24, and A16
addressing

D64, D32, D16,
D08(EO) (master)

VMEbus master D64, D32, D16, and
D08 data sizes

D64, D32, D16,
D08(EO) (slave)

VMEbus slave D64, D32, D16, and
D08 data sizes

Advertising