When switch S5 is set so that the VXIpc-800 receives the SMB CLK10
signal, you have the option to add a 50

termination to the signal by

setting switch S6. Switch S6 is unused—its setting does not matter—
when S5 is configured to drive the external CLK SMB signal.
Figure 3-5 shows the settings for switch S6.

Figure 3-5. SMB CLK10 Termination

You can use an additional switch, S4, to control the polarity of the
external CLK SMB signal when S5 is configured to drive it. S4 is
unused—its setting does not matter—when S5 is configured to receive
the external CLK SMB signal.

Figure 3-6. SMB CLK10 Polarity

S6

S6

a. Does Not Terminate CLK10

SMB Input (Default)

b. Terminates CLK10

SMB Input

S4

S4

a. Noninverted CLK10 Output

from SMB (Default)

b. Inverted CLK10 Output

from SMB