CHAPTER 9 8-BIT TIMER/EVENT COUNTERS

Count Pulse

CR10, CR20

TM1, TM2 Count Value

X-1

X

FFH

00H

01H

02H

M

N

(3) Operation after compare register change during timer count operation

If the values after the 8-bit compare registers 10 and 20 (CR10 and CR20) are changed are smaller than those

of 8-bit timer registers (TM1 and TM2), TM1 and TM2 continue counting, overflow and then restart counting

from 0. Thus, if the value (M) after CR10 and CR20 change is smaller than value (N) before the change, it

is necessary to restart the timer after changing CR10 and CR20.

Figure 9-16. Timing After Compare Register Change During Timer Count Operation

Remark

N

>

X

>

M