6

5

4

3

2

1

0

7

Symbol

SINT

0

CLD

SIC

SVAM

0

0

0

0

FF63H 00H R/W

Note 1

Address After Reset R/W

SVAM

0

1

SVA Bit to be Used as Slave Address

Bits 0 to 7

Bits 1 to 7

SIC

0

INTCSI0 Interrupt Source Selection

Note 2

CSIIF0 is set upon termination of serial interface
channel 0 transfer

CSIIF0 is set upon bus release detection or
termination of serial interface channel 0 transfer

CLD

0

1

SCK0/P27 Pin Level

Note 3

Low level

High level

R/W

R/W

R

1

(c) Interrupt timing specify register (SINT)

SINT is set with a 1-bit or 8-bit memory manipulation instruction.

RESET input sets SINT to 00H.

Caution

Be sure to set bits 0 to 3 to 0.

Notes 1. Bit 6 (CLD) is a read-only bit.

2. When using wake-up function in the SBI mode, set SIC to 0.

3. When CSIE0 = 0, CLD becomes 0.

Remark

SVA

: Slave address register

CSIIF0 : Interrupt request flag corresponding to INTCSI0