NEC PD78058FY(A) User Manual

Page 522

Advertising
background image

522

CHAPTER 23 STANDBY FUNCTION

RESET
Signal

Operating
Mode

Clock

Reset
Period

STOP Mode

Oscillation Stop

Oscillation
Stabilization
Wait Status

Operating
Mode

Oscillation

Wait

(2

17

/f

x

: 26.2 ms)

STOP
Instruction

Oscillation

(c) Release by RESET input

The STOP mode is cleared upon RESET input, and after the lapse of the oscillation stabilization time,

reset operation is performed.

Figure 23-5. Release by STOP Mode RESET Input

Remarks 1. f

X

: main system clock oscillation frequency

2. ( ): f

X

: 5.0 MHz

Table 23-4. Operation After STOP Mode Release

Release Source

MK

××

PR

××

IE

ISP

Operation

Maskable interrupt request

0

0

0

×

Next address instruction execution

0

0

1

×

Interrupt service execution

0

1

0

1

Next address instruction execution

0

1

×

0

0

1

1

1

Interrupt service execution

1

Ч

Ч

Ч

STOP mode hold

Test input

0

Ч

Ч

Next address instruction execution

1

Ч

Ч

STOP mode hold

RESET input

Ч

Ч

Reset processing

Remark

×

: Don't care