NEC PD78058FY(A) User Manual

Page 450

Advertising
background image

450

CHAPTER 19 SERIAL INTERFACE CHANNEL 2

PE

6

5

4

3

2

1

0

7

Symbol

ASIS

0

0

0

0

0

FE

OVE

FF71H 00H R

Address After Reset R/W

OVE

0

1

Overrun Error Flag

Overrun error not generated

Overrun error generated

Note 1

(When next receive operation is completed before
data from receive buffer register is read)

FE

0

1

Framing Error Flag

Framing error not generated

Framing error generated

Note 2

(When stop bit is not detected)

PE

0

1

Parity Error Flag

Parity error not generated

Parity error generated (When transmit data parity
does not match)

(c) Asynchronous serial interface status register (ASIS)

ASIS is set with 8-bit memory manipulation instruction.

RESET input sets ASIS to 00H.

Notes 1. The receive buffer register (RXB) must be read when an overrun error is generated. Overrun

errors will continue to be generated until RXB is read.

2. Even if the stop bit length has been set as 2 bits by bit 2 (SL) of the asynchronous serial

interface mode register (ASIM), only single stop bit detection is performed during reception.