CHAPTER 18 SERIAL INTERFACE CHANNEL 1

Start bit switching is realized by switching the bit order write to SIO1. The SIO1 shift order remains unchanged.

Thus, switching between MSB-first and LSB-first must be performed before writing data to SIO1.

(4) Transfer start

Serial transfer is started by setting transfer data to the serial I/O shift register 1 (SIO1) when the following two

conditions are satisfied.

Serial interface channel 1 operation control bit (CSIE1) = 1

Internal serial clock is stopped or SCK1 is a high level after 8-bit serial transfer.

Caution

If CSIE1 is set to "1" after data write to SIO1, transfer does not start.

Upon termination of 8-bit transfer, serial transfer automatically stops and the interrupt request flag (CSIIF1)

is set.

Figure 18-7. Circuit of Switching in Transfer Bit Order

7

6

Internal Bus

1

0

LSB-first

MSB-first

Read/Write Gate

SI1

Serial I/O Shift Register 1 (SIO1)

Read/Write Gate

SO1

SCK1

D

Q

SO1 Latch