How do you log alarms and events, How do you log alarms and events? -12, Table 5-2 – National Instruments BridgeVIEW User Manual

Page 149

Advertising
background image

Chapter 5

Alarms and Events

BridgeVIEW User Manual

5-12

© National Instruments Corporation

How Do You Log Alarms and Events?

Events are logged in ASCII files named in the format

YYMMDDHHMM.evt

using the timestamp of the first point to be logged.

YY

is the year,

MM

is the

Table 5-2. Event Configuration, Log, and Print Format Selections

Selection

Description

Date

Determines whether the date is logged or printed.

Date Format

A menu ring that allows you to pick a format for the date to be printed. This
selection is valid only if Date is selected. The menu items are:

MM/DD/YYYY

and

DD/MM/YYYY

.

Time

Determines whether the time is logged or printed.

Time Format

Determines the format for the time logged or printed. This selection is valid
only if Time is selected. The menu items are:

AM/PM

and

24 HOUR

.

Tag Name

Determines whether the tag name is logged or printed.

Tag Name Field
Length

Determines the maximum number of characters for the tag name.
This selection is valid only if Tag Name is checked.

Event Type

Determines whether the event name is logged or printed.

Group Name

Determines whether the group name is logged or printed.

Group Name Field
Length

Determines the maximum number of characters for the group name.
This selection is valid only if Group Name is checked.

Alarm Value

Determines whether the alarm value is logged or printed.

Alarm State

Determines whether the alarm state is logged or printed.

Alarm Ack State

Determines whether the alarm acknowledge state is logged or printed.

Alarm Priority

Determines whether the alarm priority is logged or printed.

Alarm Limit

Determines whether the alarm limit is logged or printed.

Operator Name

Determines whether the name of the current operator is logged or printed.

Operator Name
Field Length

Determines the maximum number of characters for the operator name.
This selection is valid only if Operator Name is checked.

Alarm Message

Determines whether the alarm message is logged or printed.

Alarm Message
Field Length

Determines the maximum number of characters for the alarm message.
This selection is valid only if Alarm Message is checked.

Advertising