Engine Shutdown

Use the Engine Shutdown VI to shut down the BridgeVIEW Engine from your HMI. You
must terminate your application immediately after calling this VI. The BridgeVIEW Engine
does not shut down until all VIs that are accessing the Real-Time Database finish. If you do
not terminate your application, after a few seconds a dialog box prompts you to stop your
application so that the BridgeVIEW Engine can complete shutdown.

Shutdown engine determines whether the BridgeVIEW Engine shuts
down. If TRUE, this VI notifies the BridgeVIEW Engine to shut down. If
FALSE, the VI does nothing. This parameter is TRUE by default.