Block diagram – National Instruments BridgeVIEW User Manual

Page 245

Advertising
background image

Chapter 11

Loops and Charts

BridgeVIEW User Manual

11-6

© National Instruments Corporation

8.

Rescale the knob. Using the Labeling tool, double-click on

10.0

in the

scale around the knob, and replace it with

2.0

.

Block Diagram

9.

Open the block diagram and create the diagram in the following
illustration.

a.

Place the While Loop in the block diagram by selecting it from
Functions»Structures. The While Loop is a resizable box that is
not dropped on the diagram immediately. Instead, you have the
chance to position and resize it. To do so, click in an area above
and to the left of all the terminals. Continue holding down the
mouse button and drag out a rectangle that encompasses the
terminals.

b.

Select the Random Number (0–1) function from Functions»
Numeric
.

c.

Wire the diagram as shown in the Block Diagram, connecting the
Random Number (0–1) function to the Random Signal chart
terminal, and the Enable switch to the conditional terminal of the
While Loop. Leave the Loop Delay terminal unwired for now.

10. Return to the front panel and turn on the vertical switch by clicking on

it with the Operating tool.

11. Save the VI as

Random Signal.vi

in the

BridgeVIEW\Activity

directory.

12. Run the VI.

The While Loop is an indefinite looping structure. The diagram within it
executes as long as the specified condition is TRUE. In this example, as
long as the switch is on (TRUE), the diagram continues to generate random
numbers and display them on the chart.